Abstract WP247: Enhanced Detection of Acute Ischemic Stroke with Low-Field MRI

0Citations signalées — pas une note de qualité
7Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Introduction: Portable, low-field (LF) magnetic resonance imaging (MRI) has the potential to expand access to neuroimaging in environments where conventional MRI is limited. However, diffusion-weighted imaging (DWI) at LF is challenged by a low signal-to-noise ratio and gradient strength, which may limit diagnostic confidence in acute ischemic stroke (AIS) evaluation, particularly for very small strokes. To address this gap, we evaluated a combination of novel LF-MRI hardware and pulse sequences to enhance lesion detection. Methods: Patients with a suspected diagnosis of AIS were prospectively enrolled at three US centers and underwent single-direction DWI and apparent diffusion coefficient (ADC) imaging on a 0.064 T MRI (v1, Hyperfine Inc.). A multi-direction DWI sequence (comprising 3 orthogonal diffusion direcions) was developed for comparison. Additionally, a next-generation 0.064 T scanner with optimized gradient amplifiers, form factor, and cooling system was evaluated (v2, Hyperfine Inc.). Diagnostic accuracy and the lower limit of lesion detection was calculated for both single-direction and multi-direction images compared to ground-truth MRI (1.5-3 T). Results: A total of 95 patients ( n =62 confirmed ischemic stroke; n =33 stroke mimics) were included. On single-direction images, agreement between assessors regarding lesion detection was κ=0.72, and κ=0.84 on multi-direction images. The positive predictive value for differentiating AIS from stroke mimics was 78.2% on single-direction images and 95% for multi-direction trace maps. On single-direction images, a lesion volume cut-point of 0.6 mL yielded a sensitivity of 89% and specificity of 88%. For multi-direction trace maps, the lesion volume cut-point was 0.4 mL, with a corresponding sensitivity of 86% and specificity of 83%. Multi-direction imaging on the next generation v2 hardware improved image uniformity (p<0.05), reduced scan time by approximately 30% (15 vs. 11 min), and enabled the detection of lesions as small as 0.15 mL. Conclusions: Implementation of DWI optimization strategies on LF-MRI improves detection of very small strokes in a clinically feasible time frame. These advancements highlight the potential role of portable LF-MRI as a diagnostic tool for the evaluation of patients with suspected mild stroke or transient ischemic attack, particulalrly in locations that do not otherwise have ready access to MRI.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Abstract WP247: Enhanced Detection of Acute Ischemic Stroke with Low-Field MRI
Date Crossref
01/02/2026
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsMRI in cancer diagnosis

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.