Aller au contenu principal
Accès ouvert déclaré 2026 article

Sample size and power analysis for ROC AUC differences in diagnostic tests: a methodological evaluation of the Obuchowski-McClish and Hanley-McNeil methods

6Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Sample size determination for area under the curve (AUC) comparisons in diagnostic accuracy studies requires the consideration of multiple methodological parameters. The type of diagnostic test, the nature of the data (discrete or continuous), the correlation structure between tests, and the degree of AUC differences all influence optimal study design and planning. To address these factors, this study provides comprehensive sample size and power calculations for comparing AUCs between diagnostic tests across clinically relevant scenarios. METHODS: We conducted a comprehensive evaluation of sample size and power analysis for AUC comparisons under varying correlation levels (ρ = 0.30, 0.50, 0.80), data types (discrete vs. continuous), and AUC differences (ΔAUC = 0.02–0.10). The Obuchowski–McClish method was applied for discrete data, and the Hanley–McNeil approach was applied for continuous data, assuming balanced case-control allocation and two-sided testing (α = 0.05). Sample sizes were calculated to achieve 80% statistical power based on established methodological approaches and adjusted for a 20% anticipated attrition rate. Power curves were generated to illustrate the relationship between sample size and statistical power across the evaluated scenarios. RESULTS: The required sample sizes varied substantially across scenarios, ranging from 36 − 3,709 participants per group to achieve 80% power. The degree of difference in the area under the curve (AUC) was the primary determinant: ΔAUC = 0.02 required 909-3,709 participants, whereas a ΔAUC = 0.10 required only 36–142 participants. Inter-test correlation also had a marked impact on efficiency, with a strong correlation (ρ = 0.8) reducing sample sizes by 49% in discrete models and 68% in continuous models compared with a weak correlation (ρ = 0.3). Continuous data models consistently outperformed discrete models, requiring 24–53% fewer participants across all the scenarios. The most demanding scenario (ΔAUC = 0.02, discrete data, ρ = 0.3) required 3,709 participants per group, whereas the most efficient scenario (ΔAUC = 0.10, continuous data, ρ = 0.8) required only 36 participants, representing a 103-fold difference. CONCLUSIONS: Methodological choices lead to substantial variations in sample size requirements for diagnostic accuracy studies. Optimal parameter selection, particularly the use of continuous data models and accounting for strong inter-test correlations, can reduce the required sample sizes by up to 68% compared with suboptimal combinations. These results provide evidence-based guidance for efficient planning of diagnostic accuracy studies and underscore the critical importance of methodological considerations in study design optimization.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Sample size and power analysis for ROC AUC differences in diagnostic tests: a methodological evaluation of the Obuchowski-McClish and Hanley-McNeil methods
Date Crossref
28/01/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Sepsis Diagnosis and TreatmentMeta-analysis and systematic reviewsReliability and Agreement in Measurement

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.