Safety and efficacy of radiofrequency ablation of benign thyroid nodules in patients with a history of implantable cardioverter defibrillators (ICDs), permanent pacemakers (PPMs), and implantable cardiac monitors (ICMs)
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Radiofrequency ablation (RFA) has emerged as an effective, minimally invasive treatment option for benign thyroid nodules. However, safety in patients with cardiac implantable electronic devices (CIEDs) such as implantable cardioverter defibrillators (ICDs), permanent pacemakers (PPMs), and implantable cardiac monitors (ICMs) is unclear, given theoretical risks of electromagnetic interference (EMI). As the use of both RFA and CIEDs continues to increase, establishing evidence-based safety guidance for this population is essential. This study aimed to evaluate the safety of RFA for benign thyroid nodules in patients with CIEDs. Methods: This retrospective study included 7 patients with a history of ICDs, ICMs, or PPMs and benign thyroid nodules who underwent RFA. All CIEDs were interrogated both before and after the procedure. A magnet was placed over ICDs, and electrocardiogram (ECG) monitoring was performed to detect arrhythmias or mode switching. Outcomes included the incidence of post-RFA complications, including possible cardiac implant malfunctions and volume reduction rate (VRR) at 6 months. Results: The mean age of the patients was 72.1±12.5 years, with 71.4% of the patients being female. The mean VRR at 6 months was 73.8%±24.9%. No peri-procedural complications occurred, and no patient demonstrated clinically significant EMI, inappropriate sensing or pacing, arrhythmias, device resets, or structural lead damage. All patients tolerated the procedure without adverse events. Conclusions: RFA appears to be a safe and effective treatment for benign thyroid nodules in patients with a history of ICDs, ICMs, and PPMs. Our experience demonstrated the safety of RFA and supported its utility in this high-risk population when performing these procedures with appropriate monitoring.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Safety and efficacy of radiofrequency ablation of benign thyroid nodules in patients with a history of implantable cardioverter defibrillators (ICDs), permanent pacemakers (PPMs), and implantable cardiac monitors (ICMs)
- Date Crossref
- 01/01/2026
- Éditeur
- AME Publishing Company
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Tulane University pays non établi dans la noticeUniversité ou école supérieure
-
George Washington University Department of Surgery pays non établi dans la noticeUniversité ou école supérieure
-
School of Medicine Department of Surgery pays non établi dans la noticeUniversité ou école supérieure
Tulane University, Department of Surgery — George Washington University et Department of Surgery — School of Medicine.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.