Augmented Reality‐Based Femur Registration With Head‐Mounted Display and Infrared Tracking Device as Stand‐Alone Navigation Tool: A Preclinical Validation Study
Rattachement africain : be. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background and Aims: This study evaluated the accuracy of a standalone augmented reality (AR) navigation system using the Microsoft HoloLens 2 for total hip arthroplasty (THA). The system integrates infrared (IR) tracking and a preoperative 3D CT model for intraoperative visualization and guidance. The aim was to assess whether this AR-based solution could achieve clinically acceptable accuracy for use as a surgical navigation tool. Methods: A dedicated AR application was developed to perform six-degrees-of-freedom pose estimation using inside-out tracking. Registration accuracy was assessed using six femur replicas with predefined target points. The registration pipeline combined landmark-based initialization with iterative surface refinement. Target registration error (TRE) was calculated for each point, and the influence of anatomical region, axis, surgical approach (anterior vs. posterior), and user experience level was analyzed. Results: < 0.001), with the highest errors noted along the anteroposterior axis and in distal femoral regions. No significant differences were found between anterior and posterior approaches or among users with varying levels of experience, indicating operator-independent performance. Conclusion: The AR navigation system demonstrated consistent and accurate registration performance across users and approaches. With a mean TRE of ~3 mm, the system meets accuracy requirements for potential clinical application in THA. Further cadaveric validation is recommended to confirm surgical feasibility and applicability.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Augmented Reality‐Based Femur Registration With Head‐Mounted Display and Infrared Tracking Device as Stand‐Alone Navigation Tool: A Preclinical Validation Study
- Date Crossref
- 27/01/2026
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.