Reproducibility of QQ ( QSM + qBOLD ) Oxygen Extraction Fraction ( OEF ) Mapping in the Brain at 3 and 1. 5 T
Résumé fourni par la source
PURPOSE: This study aims to assess the repeatability and reproducibility of qBOLD+QSM (QQ) oxygen extraction fraction (OEF) measurements across 3 and 1.5 T. METHODS: The effects of field strength on signal to noise ratio (SNR) and OEF sampling time were experimentally assessed in 14 healthy subjects using repeated scans performed at 3 and 1.5 T. Whole-brain and regional OEF values were analyzed using Bland-Altman and correlation between repeated scans and across field strengths. RESULTS: Whole-brain and regional OEF values showed strong agreement between repeated scans at the same field strength, with minimal differences (≤ 0.74%) and high correlation (r > 0.92). Across field strengths, comparisons similarly showed small mean differences (≤ 1.51%) and strong correlations (r > 0.95). CONCLUSION: QQ-OEF has good repeatability and reproducibility at both 3 and 1.5 T. Good performance at 1.5 T may arise from accurate noise modeling and longer sampling times at lower field strengths.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- Reproducibility of <scp>QQ</scp> ( <scp>QSM</scp> + <scp>qBOLD</scp> ) Oxygen Extraction Fraction ( <scp>OEF</scp> ) Mapping in the Brain at <scp>3</scp> and 1. <scp>5</scp> T
- Date Crossref
- 23/01/2026
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.