Head-to-head comparison of left ventricular strain assessed by CMR post-processing tools and fast strain-ENCoded imaging

0Citations signalées, ce qui n’est pas une note de qualité
8Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : de, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Aims Cardiovascular magnetic resonance (CMR) strain imaging allows early detection of subclinical myocardial dysfunction and provides incremental diagnostic and prognostic information. Strain can be derived from dedicated sequences such as fast Strain-ENCoded imaging (fSENC) or from post-processing of cine images using feature tracking (FT) and tissue tracking (TT). However, it remains unclear whether strain values from different approaches are directly comparable, making the definition of universal reference values difficult. This study compared left ventricular (LV) strain assessed by FT, TT, and fSENC. Methods and results We studied 240 individuals (183 patients recovered from coronavirus disease 2019 [COVID-19] and 57 age- and sex-matched healthy controls), who underwent standardized CMR including cine imaging and fSENC. LV global longitudinal (GLS), circumferential (GCS), and radial strain (GRS) were analysed using FT and TT; fSENC provided GLS and GCS. Global strain values differed significantly between all methods (P < 0.001). Agreement between FT and TT was high for GLS (bias −0.8%, r = 0.77) and moderate for GCS (bias −1.2%, r = 0.63), but poor for GRS (bias −6.0%, r = 0.37). Compared with fSENC, GLS showed moderate agreement for FT (bias 2.3%, r = 0.57) and TT (bias 3.0%, r = 0.59), while agreement for GCS was weaker. All approaches demonstrated excellent reproducibility. Post-COVID-19 patients showed a consistent but mild reduction in GLS compared with controls across all techniques (all P < 0.05). Conclusion CMR strain imaging provides fast, reliable, and reproducible measurements. However, strain values are not directly interchangeable even between similar post-processing methods or when compared with dedicated sequences, highlighting the need for standardization and method-specific reference values.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Head-to-head comparison of left ventricular strain assessed by CMR post-processing tools and fast strain-ENCoded imaging
Date Crossref
01/01/2026
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiovascular Function and Risk FactorsCardiac Imaging and DiagnosticsCardiovascular Disease and Adiposity

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.