Improving inter-rater reliability in radiographic edema scoring in acute respiratory failure through structured training and expert feedback
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Reproducible quantification of pulmonary edema on chest radiographs is challenging for bedside clinicians. The Radiographic Assessment of Lung Edema (RALE) score offers a structured, semi-quantitative approach with prognostic implications in acute respiratory failure (ARF), yet its clinical use is limited by the absence of standardized training. OBJECTIVE: To determine whether a standardized RALE training program, combined with expert feedback, improves inter-rater reliability across clinician experience levels. METHODS: We analyzed 4487 chest radiographs from 864 critically ill patients with ARF enrolled in a prospective registry. Sixteen physicians (1 expert and 15 reviewers-including 5 interns, 4 residents, 3 fellows, and 3 attendings) completed a 3-phase RALE training program: (i) independent review of instructional materials, (ii) a live virtual session led by the expert, and (iii) iterative practice with expert feedback on discrepant scores. All scoring was performed using the Pulmo-Annotator platform. We assessed inter-rater reliability using intraclass correlation coefficients (ICC), Bland-Altman analysis, and Deming regression, while stratifying performance by experience level and self-reported confidence. RESULTS: Inter-rater reliability improved following the training program, with ICC increasing from 0.89 (95% CI: 0.85-0.92) to 0.93 (95% CI: 0.90-0.95) after expert feedback. Fellows demonstrated the largest gain of ICC from 0.89 to 0.97, while interns and attendings maintained high reliability. Post-feedback analyses indicated reduced systematic bias. Residents exhibited the greatest variability and revised fewer scores post-feedback, despite equivalent exposure to feedback. Score distributions also varied by self-reported confidence, with greater variability among less experienced reviewers. CONCLUSION: Following a structured training program, radiographic edema scoring using the RALE framework demonstrated excellent inter-rater reliability, which further improved with targeted expert feedback. This structured training program, which incorporated standardized instructional materials and iterative feedback, demonstrated that RALE scoring is teachable across different levels of clinical experience and can be integrated into educational curricula to enhance consistency in chest radiograph interpretation. These findings provide a foundation for future work exploring the role of RALE training in broader research and clinical applications.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Improving inter-rater reliability in radiographic edema scoring in acute respiratory failure through structured training and expert feedback
- Date Crossref
- 23/01/2026
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.