Near-infrared spectroscopy monitoring in kidney transplantation: early detection of acute rejection—a case report

0Citations signalées — pas une note de qualité
7Institutions déclarées
4Pays d’affiliation déclarés

Résumé fourni par la source

Introduction Acute rejection remains a major cause of morbidity and graft loss after kidney transplantation, despite advances in immunosuppressive therapy. Conventional monitoring methods, such as serum creatinine, urine output, and Doppler ultrasound, detect graft dysfunction only after significant injury has occurred. Near-infrared spectroscopy (NIRS) is a noninvasive technique that continuously measures regional tissue oxygen saturation (rSO 2 ) and may allow earlier detection of perfusion abnormalities. Case report A 36-year-old male with end-stage kidney disease underwent living-donor kidney transplantation under general anesthesia with goal-directed fluid therapy. Postoperative NIRS monitoring was performed using a sensor placed over the graft site. The rSO 2 was approximately 95% on postoperative day (POD) 1, decreased to 78% on POD 2, and reached a nadir of 66% on POD 3, followed by gradual recovery to 91% by POD 6. Despite the apparent improvement in NIRS values, the patient developed oliguria progressing to anuria on POD 6. A renal biopsy confirmed acute rejection, and immunosuppressive therapy was promptly intensified. Discussion The early decline in rSO2 likely reflected evolving hypoperfusion, while the subsequent increase may have resulted from impaired oxygen extraction due to microvascular injury. This paradoxical trend resembles shock states, in which poor oxygen utilization leads to deceptively normal saturation levels. NIRS enables continuous, real-time assessment of graft perfusion, complementing conventional monitoring tools. However, interpretation must consider confounding factors such as tissue characteristics, light interference, and hemodynamic variability. Conclusion/take-home message Near-infrared spectroscopy (NIRS) may serve as an early, noninvasive indicator of graft dysfunction and acute rejection after kidney transplantation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Near-infrared spectroscopy monitoring in kidney transplantation: early detection of acute rejection—a case report
Date Crossref
23/01/2026
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Optical Imaging and Spectroscopy TechniquesSpectroscopy Techniques in Biomedical and Chemical ResearchOrgan Transplantation Techniques and Outcomes

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.