Aller au contenu principal
2026 article

Planimetry of Aortic Valve Area Using CTA: Cutoff Derivation for Stenotic Bicuspid and Tricuspid Valves

2Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Computed tomography based planimetric assessment of the anatomic aortic valve area (aAVA CTA ) in aortic stenosis is routinely performed. Unlike transthoracic echocardiography (TTE)-based effective AVA by TTE, it lacks clearly defined severity cutoff values, limiting clinical utility. METHODS: In this retrospective single-center analysis with computed tomography angiography data from 2013 to 2025, cutoffs were determined from 1294 TTE-based conclusive severe or nonsevere patients by congruence of maximum velocity, mean pressure gradient, and effective AVA by TTE. In separate receiver operator curves analyses for tricuspid and bicuspid valves, the severe stenosis likely cutoff was defined by Youden index and the unlikely cutoff by a negative likelihood ratio <0.1. Cutoffs were internally validated in 480 patients, compared with the Agatston score by net reclassification index, and tested in 190 separate normal-flow low-gradient aortic stenosis cases. RESULTS: Correlation between aAVA CTA and effective AVA by TTE was moderate and strong in tricuspid and bicuspid valves, respectively (Pearson r 0.67 and 0.78; P <0.001). Severe stenosis was likely in tricuspid valves at aAVA CTA ≤0.95 cm² (sensitivity 87%, specificity 78.9%) and unlikely at ≥1.10 cm² (negative likelihood ratio, 0.092). In bicuspid valves severe stenosis was likely at aAVA CTA ≤1.08 cm² (sensitivity 88.3%, specificity 77.3%) and unlikely at ≥1.20cm 2 (negative likelihood ratio, 0.091). Validation showed comparable results. Net reclassification index compared with the Agatston score was 0.16 for likely and 0.17 for unlikely cutoffs ( P <0.001). Cutoffs were applied to 190 suspected severe low-gradient cases. Adding aAVA CTA as an additional severity marker led to reclassification to nonsevere in 5.8% of cases. CONCLUSIONS: Direct planimetry of AVA is feasible and shows utility in low gradient-aortic stenosis. However, as the hemodynamic effect is impacted by valve shape, cutoff values should differentiate between tricuspid and bicuspid valves.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Planimetry of Aortic Valve Area Using CTA: Cutoff Derivation for Stenotic Bicuspid and Tricuspid Valves
Date Crossref
01/03/2026
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac Valve Diseases and TreatmentsCongenital Heart Disease StudiesAortic Disease and Treatment Approaches

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.