Aller au contenu principal
Accès ouvert déclaré 2026 article

True versus pseudo-occlusion of the cervical internal carotid artery in acute stroke: A multicenter MR angiography study

0Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : de, ch. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: Differentiating true from pseudo-occlusion of the cervical internal carotid artery (ICA) in acute ischemic stroke patients undergoing thrombectomy is crucial but challenging. We aimed to investigate the ability of contrast-enhanced magnetic resonance angiography (CE-MRA) to differentiate true from pseudo-occlusion (defined as an isolated thrombus of the intracranial ICA suppressing ascending blood flow) of the cervical ICA in acute ischemic stroke patients. MATERIALS AND METHODS: Multicenter, retrospective analysis of acute ischemic stroke patients with true or pseudo-occlusion of the cervical ICA and subsequent thrombectomy. Patients with preprocedural CE-MRA showing a lack of contrast filling in the cervical ICA on the symptomatic side were included. Six readers (three radiology fellows and three board-certified radiologists) independently evaluated the CE-MRA images for true or pseudo-occlusion of the cervical ICA using a rating scheme. Their assessments were compared with DSA results as the reference standard. Diagnostic accuracy measures, as well as inter- and intra-reader reliability for detecting pseudo-occlusion, were calculated and compared between subgroups. RESULTS: A total of 41 patients were included. The median age was 73 years, and 39% were female. According to the reference standard, 16 of 41 (39%) patients had a pseudo-occlusion of the cervical ICA, while the remainder had a true occlusion. The aggregated sensitivity and specificity from all readers were 72% (95% confidence interval [CI]: 62%-81%) and 86% (95% CI: 79%-91%), respectively. Board-certified radiologists performed better, with a sensitivity of 81% (95% CI: 67%-91%) and specificity of 92% (95% CI: 83%-97%). Overall, inter-reader agreement was moderate (κ = 0.48; 95% CI: 0.31-0.65) and reached substantial agreement within the board-certified radiologists subgroup (κ = 0.65; 95% CI: 0.45-0.85). CONCLUSION: Differentiating true occlusion from pseudo-occlusion of the cervical ICA using CE-MRA is feasible but requires training in specific imaging characteristics as well as experience in interpreting them, as evidenced by the higher diagnostic accuracy of board-certified radiologists. Correct distinction help in optimal material selection (e.g. size and type of guiding catheter) prior to endovascular treatment.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
True versus pseudo-occlusion of the cervical internal carotid artery in acute stroke: A multicenter MR angiography study
Date Crossref
01/01/2026
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Acute Ischemic Stroke ManagementCerebrovascular and Carotid Artery DiseasesAdvanced MRI Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.