Aller au contenu principal
Accès ouvert déclaré 2026 article

A Virtual Reality Simulated Alternate Cover Test to Evaluate Adults with Strabismus

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Objective Obtaining precise strabismus measurements is key in the diagnosis and management of strabismus in adults. Virtual reality (VR) has the potential to address the limitations of the standard alternate cover test (ACT) in measuring strabismus. The goal of this study was to evaluate the performance of a VR-simulated ACT in adults with strabismus. Design Prospective Cohort Study. Participants Eligible consecutive participants ≥18 years with manifest strabismus ≥5 prism diopters (PD) at either distance or near were prospectively enrolled. Intervention Each patient underwent a VR-simulated ACT with eye-tracking technology (Olleyes VisuALL) followed by an ACT by a masked pediatric ophthalmologist. Bland-Altman plots, intraclass correlation coefficient (ICC), and Spearman correlation were used to compare the limits of agreement (LOA) and association between the two exams for the entire cohort as well as those with deviations ≥10 PD. Main Outcome Measures Level of agreement between VR and standard strabismus measurements obtained from the VR and ACT. Results Of the 61 participants enrolled, 56 completed the VR test at near and 50 at distance. At distance, VR measurements were 0.88 prism diopters (PD) higher than the ACT (upper LOA: 19.3, lower LOA: -17.6). At near, VR measurements were 0.28 PD higher than the ACT (upper LOA: 26.1, lower LOA: -25.5). For patients with manifest strabismus ≥10 PD, VR measurements were 0.26 PD lower than the ACT at distance (upper LOA: 19.5, lower LOA: -20.1) and at 3.97 PD lower at near (upper LOA: 18.8, lower LOA: -2). Wider variability was observed in patients with larger deviations. Significant correlations between VR and ACT measurements were observed at distance greater than near (ICC=0.78, p<0.0001; ICC=0.57, p<0.001, respectively). Patients with deviations ≥10 PD exhibited similar agreement (ICC: 0.72, p<0.0001; near: ICC=0.64, p<0.0001). Conclusions A VR-simulated ACT demonstrated good correlation to standard strabismus measurements at distance and moderate correlation at near. The VR device underestimated deviations with larger deviations and tended to overestimate in those with smaller deviations. VR with eye-tracking technology holds promise in the assessment of adults with strabismus.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A Virtual Reality Simulated Alternate Cover Test to Evaluate Adults with Strabismus
Date Crossref
01/03/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Ophthalmology and Eye DisordersVestibular and auditory disordersOphthalmology and Visual Impairment Studies

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.