Fluoroscopic angles should be individualised when performing myocardial biopsies in children
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Ventricular perforation is a serious complication of percutaneous myocardial biopsy. Accurate orientation of the biopsy forceps toward the ventricular septum under fluoroscopy is essential to minimise this risk. However, in paediatric patients, variations in ventricular septal orientation complicate proper forceps alignment. No previous studies have addressed this variability in children. METHODS: We retrospectively analysed paediatric patients who underwent myocardial biopsy between January 2019 and June 2023. The angle of the ventricular septum relative to the sagittal plane was measured using cardiac CT. Biopsies were performed under fluoroscopic guidance, with individualised angles adjusted to align with the septum. Fluoroscopic images were used to calculate the angle between the biopsy forceps and the septum and the combined angle relative to the sagittal plane. RESULTS: Sixteen patients underwent a total of 85 biopsies; only the first biopsy per patient was included in the analysis. The mean angle of the septum was 54.3° (range: 30.0-75.0°), the mean angle between forceps and septum was 21.3° (range: 3.5-53.4°), and the combined angle relative to the sagittal plane was 75.6° (range: 45.0-115.7°). No cases of ventricular perforation were observed. CONCLUSION: Ventricular septal orientation varies significantly in paediatric patients. Individualised adjustment of fluoroscopic angles based on pre-procedural CT measurements allows accurate positioning of biopsy forceps and may reduce the risk of severe complications.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Fluoroscopic angles should be individualised when performing myocardial biopsies in children
- Date Crossref
- 01/01/2026
- Éditeur
- Cambridge University Press (CUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
The University of Tokyo pays non établi dans la noticeUniversité ou école supérieure
-
Shizuoka University of Welfare pays non établi dans la noticeUniversité ou école supérieure
-
Yaizu City General Hospital pays non établi dans la noticeÉtablissement de santé
The University of Tokyo, Shizuoka University of Welfare et Yaizu City General Hospital.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.