Aller au contenu principal
Accès ouvert déclaré 2026 article

Clinical Feasibility of Robotic-Assisted Endovascular Visceral Interventions

3Citations signalées — pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Purpose Assessment of the clinical feasibility of robot-assisted endovascular visceral interventions to reduce physical strain caused by prolonged standing and enabling remote interventions. Material and Methods Between 05/2024 and 09/2024, 45 patients were included in this prospective, single-center study. Patients scheduled for elective endovascular abdominal and pelvic interventions with superselective catheterization were assigned to manual (27 patients) or robotic-assisted treatment (18 patients). Radiation dose of the interventionalist, examination time (including preparation and follow-up), procedure duration and fluoroscopy time were compared between procedures using the CorPath GRX platform (Corindus, Waltham, MA) and conventional procedures. Technical success of robotic interventions was defined as achieving stable microcatheter positioning at the predefined target treatment point in the target vessel under robotic navigation, allowing execution of the planned therapy without conversion to manual navigation. Results 18 patients underwent robotic-assisted interventions (mean age 68 ± 12 years; 15 male), transarterial chemoembolization (TACE) ( n = 9), 99m Tc- MAA simulation (MAA)/transarterial radioembolization (TARE) ( n = 2) and prostatic artery embolization (PAE) ( n = 7). 27 comparable procedures were performed manually (mean age 68 ± 10 years; 21 male): TACE ( n = 13); MAA/TARE ( n = 7); PAE ( n = 7). 16/18 (88.9%; 95%-CI (Wilson) 67.3–96.7%) robotic-assisted procedures were technically successful, with manual conversion occurring in 2 patients (11.1%; 95%-CI (Wilson) 3.1–32.8%). Neither median fluoroscopy time nor procedural dose, procedure duration or examination time differed between the robotic and conventional interventions [19 min (IQR 19.55) vs. 31 min (IQR 19.85); p = .053; 107.85 Gycm 2 (IQR 164.03) vs. 128.00 Gycm 2 (IQR 186.20); p = .286; 65 min (IQR 35.50) vs. 59 min (IQR 49.00); p = .711; 100 min (IQR 37.50) vs. 100 min (IQR 40.00); p = .853]. In comparison with conventional procedures, the operator’s dose was lower in robotic interventions [0.000 mSv (IQR 0.000) vs. 0.005 mSv (IQR 0.005); p < .001]. Conclusion Findings from this pilot case series indicate that robotic-assisted endovascular visceral interventions are feasible and demonstrate a high technical success rate, while simultaneously providing the interventionalist zero radiation exposure through remote operation from the control room. Graphical Abstract

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical Feasibility of Robotic-Assisted Endovascular Visceral Interventions
Date Crossref
16/01/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Soft Robotics and ApplicationsHepatocellular Carcinoma Treatment and PrognosisAdvanced Radiotherapy Techniques

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.