Comparison of the diagnostic accuracy of [68Ga]Ga-Trivehexin PET/computed tomography and [18F]FDG PET/computed tomography in nodal staging of various solid tumors

2Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

OBJECTIVE: The aim of this retrospective study is to evaluate the diagnostic accuracy of [ 68 Ga]Ga-Trivehexin PET/CT compared with [ 18 F]fluorodeoxyglucose (FDG) PET/computed tomography (CT) for nodal staging in various solid tumors. MATERIALS AND METHODS: Between 2024 and 2025, a total of 15 patients with histopathologically confirmed primary or recurrent cancer were enrolled in the study. All participants underwent both [ 18 F]FDG and [ 68 Ga]Ga-Trivehexin PET/CT imaging for oncologic staging. Imaging findings were compared with histopathological results and clinical/radiological follow-up. Primary tumors, lymph nodes, and metastases were visually assessed, and maximum standardized uptake values were calculated. RESULTS: The median age of the patients was 62 years. Diagnoses included colorectal, breast, pancreatic, lung, bladder, thyroid, and endometrial cancers. Both [ 18 F]FDG and [ 68 Ga]Ga-Trivehexin PET/CT demonstrated uptake in all primary tumors. While [ 18 F]FDG PET/CT showed uptake in all lymph nodes, [ 68 Ga]Ga-Trivehexin PET/CT demonstrated positive uptake only in metastatic lymph nodes. The positive predictive value of [ 68 Ga]Ga-Trivehexin PET/CT was calculated as 100%. In contrast, [ 18 F]FDG PET/CT exhibited lower specificity, with a positive predictive value of 26.3%. CONCLUSION: This study demonstrates that [ 68 Ga]Ga-Trivehexin PET/CT offers higher specificity than [ 18 F]FDG PET/CT, particularly in benign lymph node lesions, and is effective in accurately identifying metastatic lymph nodes. Compared to [ 18 F]FDG PET/CT, 68 Ga-Trivehexin PET/CT provides lower false-positive rates and higher diagnostic accuracy, potentially reducing the need for unnecessary invasive procedures.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of the diagnostic accuracy of [68Ga]Ga-Trivehexin PET/computed tomography and [18F]FDG PET/computed tomography in nodal staging of various solid tumors
Date Crossref
15/01/2026
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Medical Imaging Techniques and ApplicationsRadiopharmaceutical Chemistry and ApplicationsPeptidase Inhibition and Analysis

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.