Automatic volumetric estimates of the left and right atrium using dynamic PET

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : se, dk. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Left (LAV) and right (RAV) atrial volumes are independent markers of cardiovascular risk in heart failure. Simultaneous assessment of myocardial blood flow (MBF) and atrial volumes might improve the clinical utility of cardiac PET. The aim of this study was to develop and validate an automated method for obtaining atrial volumes from dynamic myocardial perfusion PET scans without ECG-gating. Results The atria were segmented automatically using first-pass data from [15O]-water PET at rest, combining voxel-wise images of bolus area-under-curve and arrival time. Data of multiple patient cohorts were analyzed: retrospective method development in 36 subjects with systolic heart failure with prospective validation in 59 subjects with same-day echocardiograms (primary hypertrophic cardiomyopathy (n = 25), suspected or known cardiac amyloidosis (n = 25) and healthy controls (n = 9)). Test-retest repeatability of PET was assessed in clinical chest pain patients scanned twice on the same day (n = 15). Segmentation was successful in all scans (n=125). PET and echocardiography correlated for LAV in the development cohort (r=0.83, p<0.001) and in the validation cohort (LAV: r=0.83, RAV: r=0.77, both p<0.001). In alignment with echocardiography, PET identified statistically significant differences between healthy controls and subjects with hypertrophied hearts for LAV index: 26 (interquartile range: 24-29) versus 41 (32-51) ml/m2, p<0.001, and RAV index: 31 (25-43) versus 48 (38-61) ml/m2, p=0.003). Test-retest reproducibility was excellent for LAV (intraclass correlation coefficient ICC=0.96, repeatability coefficient RPC=8.6 ml/m2) and for RAV (ICC=0.96, RPC=11.6 ml/m2). Conclusion Left and right atrial volumes can be extracted automatically, accurately and reproducibly using dynamic PET.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.