Aller au contenu principal
Accès ouvert déclaré 2026 article

Real-Time OpenSim via IMUs for Full Body Kinematics During Gait, Sports, Exercise, and Dance Movements

2Citations signalées — pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Despite the growing demand for healthcare services due to an aging population, patients often avoid traditional rehabilitation centers due to high costs, time constraints, and discomfort experienced in laboratory or hospital settings. Home-based rehabilitation offers a promising alternative, but real-time kinematic monitoring and assessment remain challenging. We thus propose a real-time, wireless, portable approach for computing full-body kinematics through OpenSim. Twenty-two subjects performed walking, running, squatting, boxing, yoga, dance, badminton, stair climbing, and seated extremity exercise movements, while wearing 12 SageMotion inertial measurement units (IMUs). Real-time IMU kinematics were computed at 20 Hz and offline kinematics at 100 Hz and were compared with reference optical motion capture kinematics to determine accuracy. Real-time walking and stair climbing were most accurate, both with median RMSE of 5.3 deg. The most accurate joint angle was lumber rotation with median RMSE of 2.7 deg, and the overall median RMSE for all activities across all joints was 7.4 deg. Overall mean RMSE between real-time and offline IMU estimation was 0.7 deg, and mean latency from IMU data reception at the processing hub to kinematics generation was 31.7 ms. This approach could dramatically improve clinical and remote care by enabling rapid assessment and real-time biofeedback for rehabilitation, with potential to significantly enhance patient assessment and treatment outcomes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Real-Time OpenSim via IMUs for Full Body Kinematics During Gait, Sports, Exercise, and Dance Movements
Date Crossref
01/01/2026
Éditeur
Institute of Electrical and Electronics Engineers (IEEE)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Balance, Gait, and Falls PreventionProsthetics and Rehabilitation RoboticsStroke Rehabilitation and Recovery

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.