Aller au contenu principal
Accès ouvert déclaré 2026 preprint

Complementary Value of Transthoracic Echocardiography and Transcranial Doppler for Screening in Cryptogenic Stroke

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background The optimal noninvasive screening strategy for detecting patent foramen ovale (PFO) in patients with cryptogenic stroke (CS) remains uncertain. Although transthoracic echocardiography (TTE) and transcranial Doppler (TCD) are widely used, whether combining both modalities improves diagnostic performance has not been fully established. Methods Among 432 consecutive CS patients, 399 underwent collaborative screening with both TTE and TCD bubble tests performed by a multidisciplinary Heart–Brain Team, followed by transesophageal echocardiography (TEE) as the reference standard. Bubble tests were conducted at rest and during the Valsalva maneuver (VM). Diagnostic performance, concordance between modalities, and incremental value were evaluated using receiver operating characteristic analysis, Cohen’s kappa statistics, and sequential logistic regression models. Results TEE confirmed PFO in 156 patients (39.1%). Both TTE and TCD demonstrated significantly higher diagnostic accuracy during VM than at rest, with no significant difference in area under the curve between modalities under VM. Sequential logistic regression showed a significant incremental increase in predictive value when TCD during VM was added to TTE during VM (χ² increase from 271.4 to 297.2; p<0.0001). Although overall agreement between TTE and TCD during VM was substantial (κ=0.63), 54 patients (14%) showed discordant results, among whom 15 (28%) had TEE-confirmed PFO. Applying an “OR” rule (positive if either test was positive) significantly improved sensitivity compared with either modality alone, at the expense of modestly reduced specificity. Conclusions Dual screening with TTE and TCD during VM within a Heart–Brain Team framework significantly enhances sensitivity for PFO detection and reduces missed diagnoses in patients with CS. An “OR” rule interpretation represents a practical and clinically effective screening strategy.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Complementary Value of Transthoracic Echocardiography and Transcranial Doppler for Screening in Cryptogenic Stroke
Date Crossref
11/01/2026
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiovascular and Diving-Related ComplicationsAtrial Fibrillation Management and OutcomesCerebrovascular and Carotid Artery Diseases

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.