Résumé fourni par la source

AIM: Compare the diagnostic accuracy of measuring gingival recession (GR) using a digital ruler on intraoral scans with clinical measurements using a UNC-15 probe. METHODS: A prospective, observational, examiner-blinded, single-arm, cross-sectional, single-site study in adults aged 18+ with minimum of 20 teeth. All participants underwent an intraoral scan. Clinical GR was recorded on 6-sites (non-molar teeth) and 8-sites (molar teeth) by the principal examiner. Anonymised scans were assessed by the principal examiner twice (Ex1a, 1b) and two additional examiners (Ex2 and 3). RESULTS: 109 participants were assessed; all had at least one site of buccal GR. Ex1a on-scan measurements compared to clinical measurements showed 66.9% sensitivity and 92.5% specificity. There were considerable differences between central and proximal sites, central sites showed greater sensitivity 77.0% and specificity 81.4% compared to proximal sites 38.5% and 97.2% respectively. Diagnostic precision was robust, agreement for intra-examiner variability (Examiner-1a vs 1b) was 98.5% (95% CI 98.1%-98.8%). Inter-examiner variability was 78.9% (95% CI, 77.0%-80.6%) for Ex-1a-Ex-2 and 86.2% (95% CI, 84.8%-87.5%) for Ex-1a-Ex-3. CONCLUSION: Intraoral scan measurements are reproducible and can be utilised with accuracy. Measuring GR clinically is the current gold standard despite the limitations, intraoral scans can be utilised to overcome these limitations.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Diagnostic accuracy of on-scan assessments compared to clinical assessments using a periodontal probe for detecting gingival recession: A cross-sectional study
Date Crossref
01/03/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Periodontal Regeneration and TreatmentsOral microbiology and periodontitis researchOral and gingival health research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.