Improvement in positional accuracy with integrated surface- and X-ray imaging for intracranial stereotactic radiosurgery patients
Rattachement africain : se. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background and purpose Stereotactic radiosurgery (SRS) requires high positional accuracy to safely deliver large doses. This study evaluated an integrated surface- and image-guided radiotherapy (SGRT-IGRT) system by analysing (1) the agreement between thermo-optical and stereoscopic X-ray positioning, and (2) the impact of intra-fractional workflows on treatment accuracy and time. Materials and methods Data from 126 SRS patients treated with 30 Gy/3 fractions (n = 116) or 12 Gy/1 fraction (n = 10) on a Varian Truebeam STx were retrospectively analysed. Patients were positioned and monitored with Brainlab ExacTrac Dynamic, with 0.5 mm/0.5° tolerances for IGRT and 1 mm/1° for SGRT. Three workflows were investigated: (A) SGRT + IntraArc IGRT (imaging every 90° during treatment and between couch rotations); (B) SGRT + InterArc IGRT (imaging between couch rotations only); and (C) SGRT (no additional imaging after initial coplanar setup). Workflows (B) and (C) were simulated by omitting applied couch corrections. Results Median beam-on times were 5.5 min for workflow A, 5.0 min for workflow B, and 3.2 min for workflow C. The median differences between thermo-optical and stereoscopic X-ray patient positioning were ≤0.1 mm. The 3D positioning uncertainty remained within 0.5 mm (2.5th-97.5th percentile) using SGRT-IGRT. Omitting inter-arc imaging increased positional deviation ranges from 0.1-0.5 mm to 0.1–0.7 mm. Conclusion Thermo-optical and stereoscopic X-ray imaging showed good agreement within the set institutional tolerances. Inter-arc imaging increased treatment time by 2 min compared with SGRT alone but improved positioning accuracy. Intra-arc imaging added an additional small accuracy benefit at minor time cost.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Improvement in positional accuracy with integrated surface- and X-ray imaging for intracranial stereotactic radiosurgery patients
- Date Crossref
- 01/01/2026
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Lund University Medical Radiation Physics pays non établi dans la noticeUniversité ou école supérieure
-
Skåne University Hospital Department of Hematology pays non établi dans la noticeÉtablissement de santé
Medical Radiation Physics — Lund University et Department of Hematology — Skåne University Hospital.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.