Aller au contenu principal
Accès ouvert déclaré 2025 article

In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner

1Citations signalées, ce qui n’est pas une note de qualité
12Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : us, gb, cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

ABSTRACT Purpose To push the speed and resolution limit of in vivo quantitative imaging and enable estimation of quantitative tissue parameters of subtle brain structures that were previously difficult to assess. Methods This study implemented an efficient quantitative imaging approach, 3D‐SPI MRF, on the NexGen 7T scanner equipped with a high‐performance head‐only gradient and 96‐channel receiver array. To address challenges associated with performing rapid mesoscale MRF on this system, acquisition and reconstruction mitigation methods were developed and incorporated into the MRF framework, including: (i) flip‐angle‐aware dictionary fitting to account for both B 1 + inhomogeneity and voxel‐specific RF frequency response, (ii) gradient imperfection corrections via Skope measurements that incorporates a new per‐TR trajectory rewinder compensation, (iii) incorporation of rapid B 1 + and B 0 mappings into the MRF sequence, and (iv) high‐temporal motion navigation. Results Whole‐brain T 1 and T 2 maps were obtained at 560‐μm isotropic resolution within 4 min, where ablation studies demonstrated the necessity of the various mitigation methods implemented in removing bias and artifacts. For comparison, MRF data were acquired using current state‐of‐the‐art method but limited to typical whole‐body gradient specifications to demonstrate that the proposed developments resulted in ∼3× shorter scan time while producing more accurate parameter maps. Data were also acquired at ∼3.8× smaller voxel size, 360‐μm isotropic, using the developed technique, to achieve mesoscale multi‐parameter quantitative mapping in vivo. Conclusion Tailored 3D MRF acquisition and reconstruction were developed to enable fast and accurate T 1 and T 2 mapping across the whole‐brain at mesoscale resolution on the NexGen 7T scanner.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored <scp>MRF</scp> on the <scp> <i>NexGen</i> 7T </scp> Scanner
Date Crossref
30/12/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced MRI Techniques and ApplicationsMedical Imaging Techniques and ApplicationsNeurological disorders and treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.