Aller au contenu principal
Accès ouvert déclaré 2025 article

Left Bundle Branch Area Pacing in Cardiac Resynchronization Therapy: How Does It Compare to Biventricular Pacing in Terms of Electrocardiographic Parameters and Procedural Outcomes?

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : ru. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background/Objectives: Biventricular pacing (BVP) to deliver cardiac resynchronization therapy (CRT) is a standard intervention for heart failure, yet suboptimal response remains common due to challenges in left ventricular (LV) lead placement. Left bundle branch area pacing (LBBAP) has emerged as a promising alternative, offering physiological activation via direct conduction system engagement. However, comparative data on electrocardiographic (ECG) and procedural outcomes between LBBAP-CRT and BVP-CRT are limited. Methods: This retrospective, single-center study compared LBBAP-CRT and BVP-CRT in 114 patients with left bundle branch block and LV ejection fraction ≤ 35%. LBBAP-CRT was performed using a Medtronic SelectSecure™ 3830 lead via a fixed-curve sheath Medtronic C315HIS, with successful capture confirmed by ECG criteria (Qr/qR in V1, LV activation time < 100 ms). BVP-CRT involved coronary sinus LV lead placement. Outcomes included QRS duration, pacing thresholds, complications, and procedural metrics. Statistical analysis employed logistic regression to identify predictors of optimal pacing thresholds (≤1.0 V at 0.5 ms). Results: LBBAP-CRT yielded greater degree of QRS narrowing than BVP-CRT (136.7 ± 13.5 ms vs. 147.2 ± 14.6 ms, p < 0.001) and lower pacing thresholds (p < 0.05). Complications occurred in 18.1% of BVP-CRT patients (phrenic nerve stimulation, lead dislocation) versus none in LBBAP-CRT (p = 0.011). According to the multivariable analysis LBBAP-CRT was associated with an optimal thresholds (p = 0.007), alongside lower E/e′ ratio and lead impedance. Conclusions: LBBAP-CRT was associated with superior electrical resynchronization, fewer complications, and better pacing thresholds compared to BVP, suggesting its potential as a preferred CRT strategy. Larger randomized trials are needed to validate long-term outcomes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Left Bundle Branch Area Pacing in Cardiac Resynchronization Therapy: How Does It Compare to Biventricular Pacing in Terms of Electrocardiographic Parameters and Procedural Outcomes?
Date Crossref
26/12/2025
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studiesVagus Nerve Stimulation ResearchECG Monitoring and Analysis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.