Aller au contenu principal
Accès ouvert déclaré 2025 article

Assessing the robustness of an artificial intelligence segmentation model for quantitative cardiovascular magnetic resonance imaging across cardiac phenotypes

2Citations signalées, ce qui n’est pas une note de qualité
8Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: To introduce an artificial intelligence-based cardiovascular magnetic resonance segmentation algorithm (Nick) for automated quantification of function and parametric mapping across cardiac phenotypes reflecting clinical routine. METHODS: Nick was compared to manual gold standard (GS) segmentations in 359 multi-centre cases at 1.5T and 3T, consisting of 104 healthy individuals and 255 diseased patients with various cardiac phenotypes. Left and right ventricular (LV, RV) volumes and LV mass (LVM) were derived from short-axis segmentations. For parametric mapping, the LV myocardium was segmented to quantify T1 and T2 relaxation times. Statistical analysis comprised mean differences, correlation coefficients (R²), Bland-Altman analysis, tolerance range assessments, and paired boxplots. The number of slices and contours requiring manual correction was estimated based on slice-level differences. RESULTS: Nick demonstrated high agreement with the GS for LV and RV volume estimations (R²≥0.93) and LVM quantification (R²=0.86). For the ejection fractions, correlations were slightly lower (R²=0.85/0.72 for LV/RV) with small mean differences (+ 1.14%/-2.48% for LV/RV). T1 and T2 mapping values showed excellent agreement with manual reference values (R²≥0.92) and minimal biases (-1.64/0.14 ms for T1/T2). Nick underestimated LV volumes at end-diastole (-4.48 ml) and end-systole (-3.28 ml) as well as the RV end-diastolic volume (-5.14 ml) and stroke volume (-6.75 ml). Nonetheless, tolerance testing for mean deviations revealed clinically acceptable biases for all comparisons, and less than two slices per case required correction on average. CONCLUSION: Comparison to expert segmentations revealed robust performance of Nick in routine clinical cases with variable pathology, supporting its future integration into clinical workflows.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Assessing the robustness of an artificial intelligence segmentation model for quantitative cardiovascular magnetic resonance imaging across cardiac phenotypes
Date Crossref
26/12/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Imaging and DiagnosticsCardiovascular Function and Risk FactorsAdvanced MRI Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.