Aller au contenu principal
Accès ouvert déclaré 2025 article

Percutaneous left atrial appendage closure with concomitant dual-device implantation: a single-center observational study

0Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Background Percutaneous left atrial appendage (LAA) closure (LAAC) is a proven stroke prevention strategy for patients with atrial fibrillation (AF). However, incomplete sealing in complex LAA anatomies may compromise efficacy. Objectives This study evaluates the safety, feasibility, and efficacy of concomitant dual-device LAAC in multilobed anatomies, representing the largest cohort examined to date. Methods We reviewed all LAAC procedures performed at the University Hospital of Bern between 2009 and 2025. Baseline characteristics, procedural details, and follow-up data were analyzed for patients receiving dual-device LAAC. Endpoints included technical success, complications, thromboembolic events, and device-related issues. Continuous data were expressed as mean ± standard deviation or median values, while categorical data were reported as percentages. Group comparisons were conducted using t -test, Mann–Whitney U test, or chi-square test. Differences were expressed as 95% confidence intervals, and a p -value of less than 0.05 was considered significant. Results Of 1,307 LAAC procedures, 10 included dual-device implantation. The mean age of the patients was 71 years, and all patients were men. The Congestive heart failure, Hypertension, Age ≥75 years, Diabetes mellitus, prior Stroke or TIA, Vascular disease, Age 65–74 years, Sex category (CHA 2 DS 2 -VASc) and Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol (HAS-BLED) scores were 3.5 ± 1.8 and 2.9 ± 1.4, respectively. Most patients (70%) had paroxysmal AF. Preprocedural and intraprocedural transesophageal echocardiography (TEE) confirmed multilobed LAA anatomy in all cases. Half of the procedures were fluoroscopy-guided with one delivery sheath and transseptal puncture, while the other half were TEE-guided with a double sheath and two transseptal punctures. Only Amplatzer devices were used: Eight procedures employed two devices of the same type [five Amulet, three Amplatzer Cardiac Plug (ACP)], and two procedures combined different types (Amulet + ACP, ACP + Amplatzer Vascular Plug). Technical success was achieved in all cases. Within the first week, one (10%) patient experienced a clinically non-clinically relevant pericardial effusion. At 1-year follow-up (completed in nine patients), three (30%) patients developed pericarditis. No thromboembolic events, device-related thrombosis, or device embolization occurred. Conclusion In this small cohort of patients with complex multilobed LAA anatomy, concomitant implantation of two Amplatzer devices proved to be a feasible strategy with acceptable short-term safety, although potentially associated with an increased risk of pericarditis.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Percutaneous left atrial appendage closure with concomitant dual-device implantation: a single-center observational study
Date Crossref
19/12/2025
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Pericarditis and Cardiac TamponadeAtrial Fibrillation Management and OutcomesCardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.