A comparative study assessing neural recording quality and inflammatory tissue response between stiff and flexible microelectrode arrays

5Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Implantable microelectrode arrays (MEAs) are powerful tools for neurophysiological studies and hold tremendous potential as a key component of clinical neuroprostheses. However, their long-term efficacy is hampered by inflammatory responses to implantation. This study examines the impact of MEA substrate rigidity on neural recording quality and inflammatory tissue responses. We implanted stiff silicon-based and flexible polyimide-based MEAs with similar geometries in the deep brain region of the mouse striatum and performed weekly impedance and electrophysiological measurements over 4 weeks. The flexible MEAs demonstrated more reliable recording quality in terms of stable signal-to-noise ratio, single-unit yield, peak-to-peak amplitude, noise, and impedance, compared to the stiff probes, whose performance deteriorated over time. Endpoint histological analyses were performed to assess the glial scarring (Iba-1, GFAP), blood-brain barrier integrity (IgG), mechanosensitive ion channel expression (Piezo1), and neuronal population (NeuN and NF200) around the implant site. We found reduced microglial activation and IgG fouling within a 50-μm radius around the flexible MEAs compared to the stiff group. Additionally, a higher expression of Piezo1 was observed localized around the stiff MEA, correlating positively with increased Iba-1 and GFAP intensity. Our results show that flexible MEAs have improved device-tissue integration, indicated by lower inflammation levels and better recording stability. This research underscores the critical role of MEA substrate rigidity in influencing adverse tissue reactions, especially for deep brain regions. This understanding will improve our ability to design stable and reliable devices for chronic neural interface devices and beyond.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A comparative study assessing neural recording quality and inflammatory tissue response between stiff and flexible microelectrode arrays
Date Crossref
01/06/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Neuroscience and Neural EngineeringPlanarian Biology and ElectrostimulationTactile and Sensory Interactions

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.