Aller au contenu principal
2025 article

Comparison of Clinical and Digital Assessments of Peri-Implant Soft Tissue Esthetics using the Pink Esthetic Score

1Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

BACKGROUND AND AIM: The Pink Esthetic Score (PES) is a widely used index for evaluating the esthetics of peri-implant soft tissue in the anterior region. With the advent of digital technology, clinicians increasingly rely on digital tools to capture data and evaluate PES using standardized methods. This study aimed to compare the outcomes of clinical and digital assessments of peri-implant soft tissue esthetics using PES. MATERIALS AND METHODS: In this descriptive cross-sectional study, 24 patients with single implants in the anterior region were evaluated. The esthetic quality of the peri-implant soft tissue was assessed clinically and using scans obtained via an intraoral scanner, based on the PES. Scores were assigned for each parameter using a three-point scale: 0 (most differences), 1 (moderate differences), and 2 (least differences compared to the reference). Frequencies of PES scores were analyzed for each of the seven PES items, and total scores were calculated for both methods. Agreement between the two assessment methods was evaluated using weighted kappa statistics and the intraclass correlation coefficient (ICC). RESULTS: Out of 168 assessments, the clinical and digital modalities provided identical scores in 119 cases (70.8%). The weighted kappa for total scores was 0.64, indicating substantial agreement. Kappa values for individual parameters were as follows: 0.68 for mesial papilla, 0.69 for distal papilla, 0.54 for soft tissue margins, 0.66 for soft tissue contour, 0.68 for soft tissue color, 0.47 for soft tissue texture, and 0.62 for alveolar process deficiencies. CONCLUSIONS: Substantial agreement was observed between clinical and digital assessments of peri-implant soft tissue esthetics in the anterior region. Intraoral scanners offer a reliable and advantageous method for evaluating PES, providing consistency and convenience for clinicians.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of Clinical and Digital Assessments of Peri-Implant Soft Tissue Esthetics using the Pink Esthetic Score
Date Crossref
01/12/2025
Éditeur
Quintessence Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Dental Implant Techniques and OutcomesOrthodontics and Dentofacial OrthopedicsDental materials and restorations

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.