Clinical outcomes of second-generation intra-annular self-expanding transcatheter heart valve in an all-comers population with severe aortic valve disease

0Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : se, dk, be. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background and Aims The Navitor™ transcatheter aortic valve implantation (TAVI) system is a second-generation intra-annular self-expanding device featuring NaviSeal™ technology for paravalvular leak (PVL) prevention. Real-world data in diverse populations remain limited. We aimed to evaluate 30-day and 1-year outcomes of the Navitor TAVI system in a large all-comers population, including challenging anatomies traditionally associated with suboptimal results. Methods and Results This retrospective, multicenter registry (NAVICORE—NAVItor Collaborative Outcomes REgistry) included all consecutive patients (N = 736) undergoing TAVI with Navitor at three high-volume European centres between July 2021 and October 2024 (age: 80.2 ± 6.6 years, 47.2% female, 68.3% low surgical risk). Outcomes were assessed using Valve Academic Research Consortium-3 criteria. The technical success rate was 98.4%. The primary endpoint was a composite of all-cause mortality, disabling stroke, ≥moderate paravalvular leak (PVL), and valve re-intervention. Freedom from the primary endpoint at 30 days was 94.7%. At 12 months, freedom from death or disabling stroke was 89.3% and modified clinical efficacy was 81.1%. The mean transprosthetic gradient was 8.6 ± 4.9 mmHg at 1 year with an effective orifice area of 2.1 ± 0.5 cm2. More than moderate PVL occurred in 1.9% post-procedure and 1.6% at 12 months. In subgroup analyses, device success was 92.4% in severely calcified aortic stenosis, 87.1% in bicuspid valves, and 92.2% in small annuli <23 mm. Permanent pacemaker implantation was noted in 17.3% of pacemaker-naive patients. Conclusions In the NAVICORE registry, the Navitor intra-annular TAVI system demonstrated high procedural success, favourable haemodynamics and low PVL rates supporting its use across a wide range of clinical and anatomical scenarios.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical outcomes of second-generation intra-annular self-expanding transcatheter heart valve in an all-comers population with severe aortic valve disease
Date Crossref
01/10/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesInfective Endocarditis Diagnosis and Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.