Artifact reduction and diagnostic value of monoenergetic reconstructions from split-filter and dual-layer spectral detector dual-energy CT in early gastric cancer with titanium clip localization

2Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: Metal clip artifacts impair CT evaluation of early-stage gastric cancer (EGC). While various metal artifact reduction techniques exist, their application in this specific clinical context remains insufficiently explored. We assessed virtual monoenergetic images (VMIs) from two dual-energy CT (DECT) systems for reducing titanium clip artifacts in abdominal CT scans. DATA AND METHODS: Fifty-one EGC patients with gastric titanium clips underwent abdominal DECT using Siemens split-filter DECT (sfDECT) or Philips dual-layer spectral detector CT (DLSCT). Composite images (120 kVp-equivalent image) and VMIs (ranging from 40 to 140 keV) were generated for each patient. Quantitative assessment of image quality was performed by evaluating artifact reduction through noise measurements in the clip-affected region and contrast-to-noise ratios (CNRs) for both lesions and adjacent liver tissue. Two radiologists rated subjective image quality—including overall evaluation, artifacts, lesion visibility, and vascular contrast—using a five-point Likert scale. T staging accuracy on composite images and optimal keV VMIs was compared with pathologic T staging as the reference standard. RESULTS: Artifacts decreased progressively with higher keV. VMIs at 80–140 keV showed significantly fewer artifacts than composite images (p < 0.05). CNRs declined with increasing keV. Subjective artifact scores improved significantly at 80–140 keV for sfDECT and 90–140 keV for DLSCT compared to composite images. (p < 0.05). Lesion visibility peaked at 70/80 keV for sfDECT and 90/100 keV for DLSCT, while vascular contrast declined at higher keV. T staging accuracy improved from 25.8% with composite images to 80.6% at 70 keV VMIs (sfDECT), and from 30.0% to 85.0% at 90 keV VMIs (DLSCT). CLINICAL RELEVANCE STATEMENT: Combining optimal keV VMIs with composite images improved radiologists’ diagnostic confidence and enhanced T-staging accuracy in EGC patients with titanium clips, compared to composite imaging alone. CONCLUSIONS: VMIs at ≥ 80 keV significantly reduced titanium clip artifacts in our cohort but concurrently decreased image contrast. Medium-energy VMIs improve lesion visibility and T staging accuracy in EGC cases. CLINICAL TRIAL NUMBER: Not applicable.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Artifact reduction and diagnostic value of monoenergetic reconstructions from split-filter and dual-layer spectral detector dual-energy CT in early gastric cancer with titanium clip localization
Date Crossref
08/12/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Fudan University Shanghai Cancer Center Department of Radiology pays non établi dans la notice
    Établissement de santé
  • Shanghai University of Traditional Chinese Medicine Nuclear Department of Nuclear Medicine pays non établi dans la notice
    Université ou école supérieure
  • Shuguang Hospital pays non établi dans la notice
    Établissement de santé

Department of Radiology — Fudan University Shanghai Cancer Center, Nuclear Department of Nuclear Medicine — Shanghai University of Traditional Chinese Medicine et Shuguang Hospital.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced X-ray and CT ImagingCardiac Imaging and DiagnosticsRadiation Dose and Imaging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.