Quantifying molecular breast imaging uptake variability and changes in patients with breast cancer undergoing neoadjuvant therapy
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
RATIONALE AND OBJECTIVES: Best practices for quantifying longitudinal changes in 99m Tc-sestamibi uptake with molecular breast imaging (MBI) have not been established. The objective of this work is to quantify the variability of tumor-to-normal tissue 99m Tc-sestamibi uptake measurements in patient data and the resulting impact on categorizing uptake changes throughout neoadjuvant systemic therapy (NST). MATERIALS AND METHODS: In 60 patients with locoregional breast cancer undergoing NST, tumor-to-normal-tissue ratios of average contour counts ( ) and activity concentrations ( ) were calculated from physician contours on craniocaudal and mediolateral-oblique MBI images acquired at pre-NST, mid-NST, and post-NST with a commercial dual-headed system. Measurement variability was quantified in pre-NST images by using different contours and detector views. This analysis was then used to define patient-specific thresholds above which calculated and values at mid-NST and post-NST imaging had 'changed' from pre-NST values. RESULTS: Pre-NST values ranged from 1-5 to 1-100 and in general decreased by 10-30% at mid-NST and by 50-70% at post-NST. uncertainty was significantly higher than uncertainty (53% vs. 35% median value; paired t -test; P < 0.007), driven primarily by normal-tissue contour placement within the heterogeneous signal in normal breast parenchyma. In paired comparisons, a significantly higher number of cases 'changed' when the metric was derived from a single image instead of averaged across images (McNemar's test, P < 0.0125). CONCLUSION: By ensuring consistent acquisition conditions and standardizing contour definitions, robust metrics of tumor and normal-tissue uptake can be extracted from heterogenous clinical MBI data for longitudinal quantitative evaluations.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Quantifying molecular breast imaging uptake variability and changes in patients with breast cancer undergoing neoadjuvant therapy
- Date Crossref
- 03/12/2025
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.