Aller au contenu principal
Accès ouvert déclaré 2025 article

Mycobacterium chelonae outbreak investigation at a quaternary pediatric hospital following the opening of a LEED-certified critical care tower: where does water sustainability intersect with infection control?

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: Investigate the increased incidence of Mycobacterium chelonae positive respiratory cultures in hospitalized patients. DESIGN: Apply the Healthcare-Associated Links in Transmission of Nontuberculous Mycobacteria (HALT NTM) toolkit to an outbreak investigation of M. chelonae. SETTING: Quaternary-care pediatric hospital and medical center in the United States with a recently opened LEED-certified critical care tower. PATIENTS: Adult and pediatric patients with M. chelonae positive respiratory cultures between June 2022 and January 2024. METHODS: An epidemiological investigation involving clinical and laboratory practices, water management, building construction and renovation projects. Environmental sampling of air vents, water sources and endoscope reprocessing equipment was performed. M. chelonae isolates recovered from patients and the environment were analyzed using whole genome sequencing and compared for relatedness. RESULTS: Three clusters of matching environmental and patient isolates were identified. The most common environmental source of M. chelonae was ice/water dispensers with 40% positivity of sampled units. The critical care tower's water system performance and metrics were suboptimal, leading to four physical remediation activities along with a hyperchlorination treatment. CONCLUSIONS: Recent and ongoing construction along with the implementation of a LEED-certified, low-flow water system in a new critical care tower provided enhanced opportunities for M. chelonae exposure at point of use locations such as ice/water dispensers. More national infection prevention and control guidance is needed to address the infection risks from water sustainability efforts and construction activities in healthcare facilities.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Mycobacterium research and diagnosisMedical Device Sterilization and DisinfectionLiterature Analysis and Criticism

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.