Le résumé fourni par la source

BACKGROUND: High-degree AV-Block requiring pacemaker (PM) implantation is a frequent complication after transcatheter tricuspid valve replacement (TTVR), which represents a relative contra-indication to standard right ventricular (RV) lead placement. We report our experience in this patient cohort and compared different PM strategies prioritising interventional valve sparing options. METHODS: Consecutive patients treated with the EVOQUE system (Edwards Lifesciences) at our centre between January 2024 and May 2025 were included in this retrospective single centre analysis. Successful implantation of a valve sparing PM and feasibility of PM implantation were assessed. RESULTS: This analysis included 39 patients (mean age 77.3 years, 74.4% women, 8 patients with pre-existing PM). High-degree AV-Block requiring PM implantation occurred in 28.2% in our cohort (11/39 patients), the de-novo PM implantation rate was 35.5% (11/31 patients). Complete or incomplete right bundle branch block (RBBB) was the most frequent conduction system disorder after TTVR (11/31 patients). Median time from TTVR to PM implantation was six days [IQR: 2.5-13]. PM implantation was feasible in 11/11 patients (100%), no surgical lead placement was necessary. Implantation of a valve sparing PM was successful in 10/11 patients (90.9%). Leadless PM were implanted in 3/11, coronary sinus lead PM in 7/11 patients. In one patient both interventional valve sparing PM approaches failed and a standard RV lead across the EVOQUE system was implanted. CONCLUSION: High-degree AV-Block after TTVR is a frequent complication and PM implantation in these patients demands careful consideration. Valve sparing PM approaches appear feasible and were achieved with reasonable success rates in our cohort.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Strategy for pacemaker implantation following transcatheter tricuspid valve replacement: A real world single centre experience
Date Crossref
04/12/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsCardiovascular Function and Risk FactorsPulmonary Hypertension Research and Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.