Aller au contenu principal
Accès ouvert déclaré 2025 conference-abstract

P94 The microbiota of the hospital environment

0Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : gb, ca, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Healthcare-associated infections (HAIs) are a significant public health issue. HAIs cause extended hospital stays, increased mortality, reduced quality of life and cost the NHS an estimated £2.7 Billion annually. In 2023, the most reported HAI bacterial pathogens in England were Escherichia coli (16.5%) and Staphylococcus aureus (10.6%). In healthcare, infection prevention and control (IPC) teams use evidence-based interventions to control the spread of infectious agents. The built environment is a potential reservoir for pathogens, and surfaces frequently touched by healthcare workers, patients and/or visitors are known to play a role in HAI transmission. To minimize infection spread, IPC cleaning protocols routinely include hydrogen peroxide fumigation (known as Deprox) to decontaminate a room following discharge of a patient with an infection. Commercial adenosine triphosphate (ATP) luminometers are widely used to monitor cleaning protocols in clinical settings. However, ATP detection methods have limitations including no clear industry standards and the ability to detect a variety of biological contaminants (e.g. non-pathogenic microorganisms and organic soil). Objectives and methods To explore the hospital environmental microbiome, we performed ATP detection, 16S rRNA sequencing and quantitative PCR on various sampling sites (door, floor, sink, bed tray and wall) in side-rooms shortly after patient stays. In addition, for a subset of rooms we analysed two sample areas before and after Deprox, to assess the impact of decontamination on the environmental microbiome. Results Bacterial burden data was used to inform quality control for the microbiome analyses, and 64% of samples were defined as having a significant microbiome. A few taxa were found consistently in all areas sampled: Escherichia-Shigella, Staphylococcus, Corynebacterium and Streptococcus. Acinetobacter was identified in all sample areas, excluding wall samples. Some taxa appeared to be more predominant in one sampling site, including Bacteroides in floor samples, and Methylobacterium in sink samples. ATP levels and microbiome diversity varied significantly between the areas sampled, with the highest levels found in floor then bed-tray samples. Bacterial burden was also highest in floor samples. ATP levels dropped significantly following the decontamination procedure and 70% of samples were below a ‘strict’ RLU cutoff of 250 (all were below a commonly used RLU cutoff of 500). Although not significant, there were reductions in bacterial burden and microbiome diversity following Deprox. However, 37% of samples had a significant microbiome remaining after Deprox. Overall, ATP levels did not significantly correlate with bacterial burden or microbiome diversity. Conclusions Although it gives a useful indication of surface cleanliness, ATP monitoring does not give a clear picture of the bacteria present in the environment. Molecular analyses provided a detailed insight into the bacterial burden and specific Genera present in the environment and identified pathogen-containing Genera in all sample sites tested. As ATP levels did not correlate with bacterial burden or diversity, the viability of the potential pathogenic bacteria in the environment is unclear. Future studies are needed to investigate the viability of common pathogens in the hospital environment and further our understanding of the potential environmental reservoir for HAIs.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
P94 The microbiota of the hospital environment
Date Crossref
01/12/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • University of Manchester Division of Infection Immunity and Respiratory Medicine pays non établi dans la notice
    Université ou école supérieure
  • Manchester University NHS Foundation Trust Research and Innovation pays non établi dans la notice
    Établissement de santé
  • Institute of Infection and Immunity pays non établi dans la notice
    Structure de recherche
  • Manchester University pays non établi dans la notice
    Université ou école supérieure

Division of Infection Immunity and Respiratory Medicine — University of Manchester, Research and Innovation — Manchester University NHS Foundation Trust et Institute of Infection and Immunity, avec 1 autre affiliation.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Infection Control in HealthcareInfection Control and VentilationHealthcare Facilities Design and Sustainability

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.