Two-dimentional shear wave elastography as an alternative method of ultrasound for major salivary glands evaluation in Sjögren's disease
Rattachement africain : br, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVES: This study aimed to investigate the performance of 2-dimensional shear wave elastography (2D-SWE) in the assessment of major salivary glands (MSG) involvement in patients with Sjögren's disease (SjD), compared with B-mode ultrasound (B-mode US), both individually and in combination, and to evaluate the association between elastography parameters and clinical and laboratory data. METHODS: This cross-sectional study included 52 patients with SjD and 48 age, sex and ethnicity-matched healthy controls. Clinical and laboratory characteristics of the patients were recorded. MSG were assessed by B-mode US, and 2D-SWE, in both parameters [elasticity and shear wave velocity (SWV)]. RESULTS: B-mode US and SWE parameters revealed significant differences between patients with SjD and healthy controls. Analysis of the four MSG combined demonstrated that SjD patients had higher values of elasticity (15.2±2.9 vs. 9.3±0.8 kPa; p<0.001) and SWV (2.2±0.2 vs. 1.8±0.1m/s; p<0.001) compared with controls. Both elasticity and SWV showed excellent diagnostic performance for SjD (AUC=0.982 and 0.983, respectively). Comparatively, the elastography parameters showed higher AUCs than B-mode US (AUC=0.852). Combining both methods provided superior predictive ability (AUC=0.985) compared to isolated use of B-mode US. No significant correlations were observed between SWE parameters and clinical or laboratory features, except for the glandular domain of the ESSDAI (r=0.286; p=0.040). CONCLUSIONS: Elastography seems to be a promising tool for providing additional diagnostic value in SjD. 2D-SWE, either alone or in combination with B-mode US, may contribute to the assessment of MSG as a quantitative, non-invasive and feasible imaging method. However, further studies are needed to validate this technique.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Two-dimentional shear wave elastography as an alternative method of ultrasound for major salivary glands evaluation in Sjögren's disease
- Date Crossref
- 28/07/2025
- Éditeur
- Clinical and Experimental Rheumatology
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.