Effect of combined version on impingement-free rotational range-of-motion in three different implant types in reverse shoulder arthroplasty

1Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Background: The influence of combined humeral and glenoid component version on impingement-free range-of-motion (ROM) has not previously been evaluated in reverse total shoulder arthroplasty (rTSA). The purpose of this study was to determine the effects of combinations of humeral and glenoid component version on ROM in 3 different rTSA designs. We hypothesized that increased combined retroversion would decrease ROM. Methods: Nine patients with posterior glenoid bone loss indicated for rTSA underwent preoperative computed tomography of the shoulder. Virtual templating was performed using 3 different rTSA designs: medial glenoid-medial humerus, medial glenoid-lateral humerus (MG-LH), and lateral glenoid-medial humerus (LG-MH). Each implant was placed in different combinations of glenoid (10°, 0°, -10°, -20°) and humeral component version (0°, -10°, -20°, -30°, -40°). Virtual simulations of glenohumeral ROM were performed at 0°, 30°, and 90° abduction, with impingement-free internal rotation (IR), external rotation (ER), and combined IR and ER measured. A scapular contact mesh was created to determine impingement locations. A linear mixed effects model was used to assess the association between implant type and ROM. Chi-square tests were used to evaluate differences in impingement locations between implant types. Results: < .001). Conclusion: This study demonstrates that total impingement-free ROM in rTSA decreases with combined component version greater than 30° of retroversion. The study also demonstrates increased total ROM with implant designs that create a more lateralized center of rotation (MG-LH, LG-MH). Impingement location changes with implant design, with less scapular neck impingement found with the LG-MH design. The study is limited by not being able to account for scapulothoracic motion or soft tissue considerations.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Effect of combined version on impingement-free rotational range-of-motion in three different implant types in reverse shoulder arthroplasty
Date Crossref
01/03/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Shoulder Injury and TreatmentShoulder and Clavicle InjuriesTotal Knee Arthroplasty Outcomes

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.