Reliability of Contrast-Enhanced MR Angiography in Evaluation of Nitinol Stent Restenosis in Iliac Arteries
Rattachement africain : sk, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
In this observational study, contrast-enhanced MR angiography (MRA) was evaluated against digital subtraction angiography (DSA) in the stented segments of the iliac arteries to determine MRA's accuracy in diagnosing restenosis following stent placement. Six radiologists independently evaluated the degree of restenosis in the MRA and DSA images of 87 nitinol stents implanted in 53 patients with peripheral arterial disease. The differences in restenosis assessment between these two modalities, along with inter-observer agreement, were analysed using DSA as a reference. Discrepancy between methods was quantified by the MRA-DSA difference in % restenosis. Correlation, regression, and agreement analysis tools were used for evaluation. A significant mean MRA-DSA difference of 14.0% ( P < 0.001) in the assessment of restenosis severity between the MRA and DSA was found. In isolated cases, the discrepancy reached 50–60%. The discrepancy negatively correlated with the degree of restenosis, showing a systematic proportional bias. The agreement analysis revealed a good-to-excellent inter-observer reliability measured by the intraclass correlation coefficient ICC. In general, the DSA observers were more similar and consistent in their ratings compared to the MRA observers (0.876 and 0.651, respectively). Diagnostic performance of the MRA in detecting high-grade (≥ 50%) restenosis yielded a sensitivity of 78.57% and a specificity of 67.12%. MRA showed an acceptable-to-good sensitivity and specificity for diagnosing high-grade restenosis after placement of nitinol stent in iliac arteries, though it significantly overestimated lumen diameter narrowing at low-grade restenosis.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Reliability of Contrast-Enhanced MR Angiography in Evaluation of Nitinol Stent Restenosis in Iliac Arteries
- Date Crossref
- 02/12/2025
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.