Aller au contenu principal
Accès ouvert déclaré 2025 article

Safety, Efficacy, and Mid-Term Outcomes of Pulsed Field Ablation for Cavotricuspid Isthmus–Dependent Flutter: Real-World Data From a Major Health System Registry

8Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Cavotricuspid isthmus (CTI) ablation is frequently performed either as a standalone procedure or in combination with pulmonary vein isolation. With the rapid adoption of pulsed field ablation for atrial fibrillation, it is essential to delineate the utility of this modality in treating CTI-dependent atrial flutter (AFL). This study aims to evaluate the procedural and clinical outcomes of CTI ablation using pulsed field energy. METHODS: We conducted a retrospective analysis of consecutive patients who underwent pulsed field ablation for CTI-dependent AFL between January 2024 and March 2025. The primary end points were acute procedural success, periprocedural complications, and CTI-dependent AFL recurrence during follow-up. RESULTS: A total of 132 patients underwent CTI nonthermal ablation. The median age was 69.5 years, and 27.3% were female. The Farawave catheter was used in 93.9% of cases, PulseSelect in 4.5%, and Sphere-9 in 1.5%. Acute block was achieved in 99.2% of patients, although 8 required adjunctive radiofrequency ablation to complete the line. Periprocedural complications included transient ST-segment elevation in 2 patients and transient conduction disturbances in 3. During a median follow-up of 114 days (n=131), 5 patients (3.8%) experienced recurrence of typical AFL. The 6-month typical AFL-free survival estimate was 93.6%. CONCLUSIONS: Pulsed field ablation appears to be a feasible and effective strategy for CTI-dependent AFL. However, anatomic variability may limit its universal applicability with current catheter designs. Although acute procedural success is high, the long-term durability of the CTI block and its comparative efficacy versus conventional thermal ablation remain areas requiring further investigation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Safety, Efficacy, and Mid-Term Outcomes of Pulsed Field Ablation for Cavotricuspid Isthmus–Dependent Flutter: Real-World Data From a Major Health System Registry
Date Crossref
01/12/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Arrhythmias and TreatmentsVascular anomalies and interventionsAtrial Fibrillation Management and Outcomes

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.