Aller au contenu principal
2025 conference-paper

Analysis of failure causes and research on improvement measures for external constant magnetic field testing of electric energy meters

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The external constant magnetic field test is a pivotal method for evaluating the magnetic interference immunity of electricity meters, with its test results critically determining the metrological accuracy and operational reliability in real-world applications. This study conducts a systematic analysis of failure mechanisms in electricity meters during external constant magnetic field testing, identifying three primary failure causes: (1) structural design deficiencies, including inadequate magnetic shielding design and improper magnetic material selection; (2) magnetic susceptibility of critical components, evidenced by magnetic saturation effects in current sensors and parasitic interference from magnetic elements; and (3) circuit design flaws, characterized by insufficient anti-interference circuitry and defective grounding/shielding systems. Based on the failure mechanism analysis, this study proposes improvement strategies encompassing optimized magnetic shielding design, adoption of high magnetic-resistance materials, and enhanced circuit-level interference immunity. Experimental results demonstrate that material-based solutions outperform software algorithm optimizations in effectively addressing test failures. The enhanced prototype successfully passed the external constant magnetic field test (400 mT ± 10 mT), with all performance metrics fully complying with the IEC 62052 series of international standards and GB/T 17215 series of national standards. This research provides both theoretical foundations and practical guidance for ensuring stable operation of electricity meters in complex electromagnetic environments.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Analysis of failure causes and research on improvement measures for external constant magnetic field testing of electric energy meters
Date Crossref
01/12/2025
Éditeur
Institution of Engineering and Technology (IET)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Magnetic Field Sensors TechniquesAdvanced Electrical Measurement TechniquesElectromagnetic Fields and Biological Effects

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.