Aller au contenu principal
Accès ouvert déclaré 2026 article

Transformer-based cardiac substructure segmentation from contrast and non-contrast computed tomography for radiotherapy planning

0Citations signalées — pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Background and Purpose: Accurate segmentation of cardiac substructures on computed tomography (CT) scans is essential for radiotherapy planning. This study evaluated whether pretrained transformers enabled data-efficient training using a fixed architecture with balanced curriculum learning while achieving robust generalization to imaging and patient variations. Materials and Methods: A hybrid pretrained transformer-convolutional network, self-distilled masked image transformer (SMIT), was fine-tuned using lung cancer patient scans (Cohort I, training N = 180) and tested on held-out Cohort I lung cancer scans (testing N = 60) and breast cancer scans (Cohort II, N = 65). Two configurations were evaluated: SMIT-Balanced (32 contrast-enhanced CTs, 32 non-contrast CTs) and SMIT-Oracle (180 CTs). Performance was compared with nnU-Net and TotalSegmentator. Segmentation accuracy was assessed primarily using the 95th percentile Hausdorff distance (HD95), along with radiation dose and overlap-based metrics as secondary endpoints. Results: SMIT-Balanced approached SMIT-Oracle performance despite using 64% fewer training scans, with mean HD95 of 6.6 versus 5.4 mm in Cohort I and 10.0 versus 9.4 mm in Cohort II. On the Cohort I held-out test set, SMIT-Balanced mean HD95 was within 1.0 mm of nnU-Net. Cross-cohort testing showed larger accuracy degradation with nnU-Net than SMIT-Balanced (62% versus 50%, absolute change 4.5 mm versus 3.4 mm). Dose metrics derived from SMIT-Balanced were equivalent to manual delineations. Conclusions: Balanced curriculum training reduced labeled data requirements within the SMIT architecture. SMIT-Balanced was comparable to nnU-Net on Cohort I held-out data and showed smaller cross-cohort HD95 degradation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Transformer-based cardiac substructure segmentation from contrast and non-contrast computed tomography for radiotherapy planning
Date Crossref
01/05/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advanced Radiotherapy TechniquesMedical Imaging Techniques and ApplicationsLung Cancer Diagnosis and Treatment

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.