Comparison between single‐ and dual‐platform flow cytometry for CD34 + stem cell enumeration in a pediatric population

1Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: CD34+ hematopoietic progenitor cells (HPCs) enumeration is essential for stem cell collection adequacy. Both single (flow cytometer only) and dual-platform (flow cytometer and hematology analyzer calculation) methodologies are used, but their comparative accuracy and implications for pediatric patients remain unclear. STUDY DESIGN AND METHODS: We conducted a retrospective review of 131 autologous apheresis (HPC(A)) collections from 120 pediatric patients at a single institution (2017-2023). Assessment included differences between the two platforms as absolute and percent differences and agreement, systematic bias and association between hematology analyzers and patient characteristics with CD34+ percent differences. The impact on whether additional days of collection would be needed was assessed by comparing CD34+ dose thresholds. RESULTS: Absolute CD34+ counts were highly correlated but exhibited systematic bias. Single platform absolute CD34+ were significantly higher, especially in HPC(A). Percent differences averaged 6.3% in peripheral blood and 15.9% in HPC(A). Enumeration discrepancies varied by hematology analyzer and patient characteristics. Age, weight, and type of disease affected enumeration consistency between platforms. In 3 of 10 patients, the enumeration method potentially impacted the number of collection procedures, as the minimum CD34+ dose thresholds were met using single platform but not with dual. DISCUSSION: wEnumeration methods impact CD34+ counts and may alter clinical decisions regarding collection adequacy and need for additional days of collection. One must understand the variability in each testing methodology as it may translate to a clinically significant outcome. Method-specific adjustments or standardization protocols may be needed to ensure accurate interpretation in pediatric care.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Comparison between single‐ and dual‐platform flow cytometry for <scp>CD34</scp> + stem cell enumeration in a pediatric population
Date Crossref
27/11/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hematopoietic Stem Cell TransplantationSingle-cell and spatial transcriptomicsAcute Lymphoblastic Leukemia research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.