Aller au contenu principal
Accès ouvert déclaré 2025 article

Multiparametric MRI Markers Associated with Breast Cancer Risk in Women with Dense Breasts

1Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background/Objectives: This study explored the associations of normal breast tissue characteristics on multiparametric MRI with clinical assessments of breast cancer risk in women with dense breasts. Methods: Women with dense breasts who underwent multiparametric MRI were included. Breast cancer risk was determined based on Tyrer–Cuzick (TC) lifetime risk scores, categorized as high (TC ≥ 20%) or low risk. Qualitative background parenchymal enhancement (BPE) assessment was obtained from imaging reports. Quantitative imaging markers were calculated, including median BPE, median apparent diffusion coefficient, and volume measures of the whole breast, fibroglandular tissue (FGT), blood vessels, and BPE regions. The associations between imaging markers and TC risk groups were evaluated using age-adjusted logistic regression and summarized by area under the receiver operating characteristic curve (AUC). Results: Seventy-seven women were evaluated; a total of 20 (26%) were low risk, and 57 (74%) were high risk. After adjusting for age and multiple testing, BPE:breast ratio (adj. p = 0.037), FGT:breast ratio (adj. p = 0.046), and BPE:vessel ratio (adj. p = 0.037) were positively associated with risk, while qualitative BPE was not (adj. p = 0.11). Overall, risk categorizations based on imaging markers were concordant with TC score in up to 70% of women. Conclusions: In women with dense breasts, quantitative measures from multiparametric MRI (BPE:breast, FGT:breast, and BPE:vessel ratios) moderately discriminated high- and low-risk groups, warranting further investigation of their value to supplement conventional breast cancer risk assessment tools.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Multiparametric MRI Markers Associated with Breast Cancer Risk in Women with Dense Breasts
Date Crossref
26/11/2025
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

MRI in cancer diagnosisRadiomics and Machine Learning in Medical ImagingCancer Risks and Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.