POLAR-2 is a next-generation space astronomy platform led by China, with its core scientific objective focused on high-precision polarization measurements of gamma-ray bursts. As one of its key payloads, the Low-energy Polarization Detector (LPD) is designed to perform wide-field surveys to capture X-ray polarization information from gamma-ray bursts in the 2$\sim$10 keV energy range. This paper presents Topmetal-L, a dedicated charge-sensitive pixel sensor developed for the LPD prototype upgrade. Fabricated in a 130 nm CMOS process in 2024, the chip integrates a 356 $\times$ 512 pixel array with a pixel pitch of 45 $μ$m. Each pixel incorporates a 26 $\times$ 26 $μ$m$^2$ charge-collecting window and is capable of simultaneously outputting both energy and position information of deposited charges. Topmetal-L has been systematically optimized for power consumption, noise performance, and readout efficiency. It exhibits an input dynamic range of 0$\sim$4 ke$^{-}$, a typical charge-to-voltage conversion gain of 76.04 $μ$V/e$^{-}$, an average equivalent noise charge of approximately 22.8 e$^{-}$, a sensitive area exceeding 3.69 cm$^2$, and a total power consumption of 720 mW per chip. To meet the requirements of large-area, high-frame-rate readout for gas-based polarization detectors, a sentinel readout scheme is proposed, reducing the full-frame readout time to 730 $μ$s. A prototype Topmetal-L-based gas polarization detection system was evaluated across key energies: it exhibited a residual modulation of 0.26% $\pm$ 0.45% at 5.90 keV, a modulation factor of 66.67% $\pm$ 0.45% for a linearly polarized 8.05 keV source, and a count rate saturated at 15 k counts$\cdot$cm$^{-2}$$\cdot$s$^{-1}$ when tested at 5.40 keV.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Particle Detector Development and PerformanceCCD and CMOS Imaging SensorsGamma-ray bursts and supernovae

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.