Calibration of bronchial methacholine challenge: Addressing dose accuracy and practicality.

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : dk. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Methacholine bronchial provocation (BMP) is a valuable tool in supporting the diagnosis of asthma, but the BMP must be validated regarding dosing, since the BMP basically is a dose response study. Historically the dose delivered by a nebulizer has been calibrated gravimetrically, by weighing the nebulizer before and after dosing. However, this method is no longer recommended, since it has been recognized that a large fraction of the weight loss was due to evaporation. Unfortunately, practical alternatives are not available, forcing clinicians to rely on manufacturer specified dose output. We studied the validity of the dose claimed to be delivered by the Vyaire APS-Pro. Methods: To determine dose output we applied a radioactive method, considered the gold standard, and we validated a commercially available chemical analysis of chloride. Results: The output from the APS-Pro was found to be highly correlated (R²=0.94) with the dose specified by the APS-Pro software but was consistently higher (y=208+1,33 x (µg)). The new chemical method demonstrated accuracy comparable to the radiometric approach. Notably, we observed significant variations in output across different nebulizers. Discussion: The methacholine dose delivered to the mouth via the APS-Pro does not align with company specifications due to variability between nebulizers and a non-linear relationship between nebulization time and output, leading to higher output rates during shorter nebulization periods. Conclusion: Individual output calibration of specific BMP systems remains necessary, as current systems still do not consistently meet manufacturer specifications. Clinicians must therefore have access to practical calibration methods.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Calibration of bronchial methacholine challenge: Addressing dose accuracy and practicality.
Date Crossref
27/09/2025
Éditeur
European Respiratory Society
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Asthma and respiratory diseasesInhalation and Respiratory Drug DeliveryRespiratory and Cough-Related Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.