Aller au contenu principal
2025 conference-abstract

Predicting night to night variability (NTNV) in obstructive sleep apnea (OSA) screening in trisomy 21 (T21)

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: 3-night home pulse oximetry (3NHPO) is used for OSA screening in T21 due to presumed NTNV. Aim: To establish if threshold values can be used to predict variability across 3NHPO. Methods: All children ≥12 months with T21 undergoing OSA-screening 3NHPO from April 2020-December 2024 at our centre were included. Studies with <4 hours artefact-free recording time on any night were excluded. Clinically-relevant cut-off (CRCO) values predictive of obstructive apnea hypopnea index (OAHI) ≥5 are: Oxygen Desaturation Index 3% (ODI3) ≥6.150, delta 12s index (D12) ≥0.555, calculated combined score ≥-0.5537 (Hill, C.M. et al. Arch Dis Child 2018;103(10):962-967). Combined score = -20.988+(1.408xD12)+(0.066xODI3)+(0.178xmeanSpO2)+(0.023xminimumSpO2). Cases of change (COC) were where indices fluctuated above and below these CRCO across 3 nights. Receiver-Operator Curve analysis determined threshold values either side of CRCO with optimum sensitivity and specificity to predict COC on subsequent nights. Negative (NPV) and positive predictive values (PPV) were calculated for the threshold values. Results Of 230 eligible 3NHPO, 80 had insufficient data. 150 studies were analysed from 97 patients age 1.0-17.3 years (median 6.6). NTNV was present (for each parameter, COC in 1/3). NPV for threshold values of ODI3 <3.605, D12 <0.485 and combined score <-0.8616 were 79%, 81% and 94% respectively – children below these thresholds on night 1 are unlikely to have indices predictive of OAHI ≥5 on subsequent nights. Conclusion Where only one night of oximetry data for OSA screening in a child with T21 is available, lower threshold values than established CRCO may be used to make allowance for NTNV.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Predicting night to night variability (NTNV) in obstructive sleep apnea (OSA) screening in trisomy 21 (T21)
Date Crossref
27/09/2025
Éditeur
European Respiratory Society
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Obstructive Sleep Apnea ResearchCongenital Heart Disease StudiesDelphi Technique in Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.