Aller au contenu principal
Accès ouvert déclaré 2025 article

Safety profile of lutein-based blue dyes and surgical lights

0Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : it, es. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction The combination of surgical endoillumination and vital dyes has been associated with phototoxicity and retinal damage, despite vital dyes being mainly considered safe. Based on this perspective, the aim of the present study was to evaluate the effect of lutein-based blue dyes (LBBDs) on human retinal pigmented epithelial (ARPE-19) cells and their combination with surgical light exposure. Methods ARPE-19 cells were exposed to LBBDs and/or xenon/LED light according to the following experimental design: phase I, exposure to LBBDs only; phase II, exposure to lights only; phase III, single sequential exposure to LBBDs and xenon/LED light; and phase IV, double sequential exposure to LBBDs and xenon/LED light. ATPlite and reactive oxygen species (ROS) detection assays were used to assess the impact on cell viability and ROS production, respectively. Results No cytotoxic effect was detected following the exposure to LBBDs for 5 min. LED and xenon lights elicited a cytotoxic effect and an overproduction of ROS for an exposure time of ≥5 min. The ROS overproduction following 5-min exposure of ARPE-19 cells to both LED and xenon lights was significantly ( p < 0.05) counteracted by pre-treatment with LBBDs. Finally, after double sequential exposure to LBBDs and LED/xenon lights, 2% LBBD induced a significant ( p < 0.05) reduction in ROS production compared to both LED/xenon exposure and 1% LBBD/light exposure. Discussion These findings demonstrated the primary role of light-induced damage as a primary contributing factor to potential retinal damage following peeling procedures. LBBDs provided a protective effect against light-induced oxidative damage, highlighting their potential role in enhancing the safety profile of staining in retinal surgery.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Safety profile of lutein-based blue dyes and surgical lights
Date Crossref
24/11/2025
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Retinal and Macular SurgeryIntraocular Surgery and LensesOcular Infections and Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.