Comparing Effectiveness and Safety of Left Atrial Appendage Closure Devices: A Network Meta‐Analysis of Randomized Controlled Trials
Résumé fourni par la source
ABSTRACT Introduction Atrial fibrillation‐related stroke is a leading cause of morbidity and mortality. The comparative effectiveness and safety of left atrial appendage closure (LAAC) devices, compared with one another and with anticoagulation, is unclear. Methods We conducted a systematic review and network meta‐analysis (NMA) of all clinical trials comparing the Watchman and Amplatzer Amulet LAAC devices with each other or with warfarin or direct oral anticoagulants (DOACs). The primary comparison was between LAAC devices with secondary comparisons to anticoagulation. The primary effectiveness outcomes were any stroke and all‐cause death. Safety outcomes included any thromboembolism, device embolization, and pericardial effusion. Results There were 476 articles identified from the search and 6 eligible RCTs were included ( n = 3666). There was no difference in the risk of stroke with Amulet versus Watchman (RR = 1.48, 95% CI: 0.64–3.46, I 2 = 41.3%), nor in the risk of death (RR = 1.00, 95% CI: 0.59–1.70, I 2 = 45.0%). Risk of thromboembolism was not significantly different with Amulet versus Watchman (RR = 0.73, 95% CI: 0.18–2.97, I 2 = 0%), nor was risk of device embolization (RR = 2.29, 95% CI: 0.71, 7.43, I 2 = 0%). Both devices exhibited increased risk of pericardial effusion compared with warfarin, with Amulet at highest relative risk (RR = 27.08, 95% CI: 3.53–207.98, I 2 = 0%) followed by Watchman (RR = 12.79, 95% CI: 1.73–94.85, I 2 = 0%). Amulet also carried higher relative risk of pericardial effusion than Watchman (RR = 2.12, 95% CI: 1.45–3.09). Conclusion In this NMA, the Amulet and Watchman LAAC devices were associated with similar risks for stroke, mortality, thromboembolism, and device embolization. Pericardial effusion risk was higher with Amulet than Watchman.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Comparing Effectiveness and Safety of Left Atrial Appendage Closure Devices: A Network Meta‐Analysis of Randomized Controlled Trials
- Date Crossref
- 01/11/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.