Aller au contenu principal
Accès ouvert déclaré 2025 article

Biogenic polymer-based heart valve for congenital cardiac surgery

1Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : de, ch, Afrique du Sud. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background Current heart valve prostheses in congenital cardiac surgery (CCS) are unable to grow, remodel, or adapt to a child's evolving physiology, resulting in increased mortality rates due to material-related limitations. The excellent biocompatibility and hemocompatibility of bacterial cellulose (BC) make it a promising alternative. This study aimed to use BC to develop a biogenic polymer-based heart valve and then to assess its hemodynamic performance and long-term durability. Methods Heart valve leaflets were produced via a standard BC protocol and compressed to a minimal thickness, and their biomechanical properties were evaluated. Using a customized template, BC leaflets were sutured into a 23-mm stent scaffold. Two prototype series with different leaflet designs were tested in a mock circulatory flow loop model with a flow rate of 5 L/minute at 120/80 mm Hg. Long-term durability was assessed for 10 ± 0.5 million cycles at 120/80 mm Hg, followed by retesting. Results BC valve leaflets exhibited a thickness reduction of 94.01% to 0.3 ± 0.11 mm ( P < .001) while retaining a durability of 100% at 500 mm Hg (n = 23), with a maximum tensile strength of 1.64 ± 0.3 MPa (n = 35). All valves combined (n = 21) displayed a mean transvalvular pressure drop (MTP) of 8.32 ± 1.23 mm Hg, a mean regurgitation fraction (REG) of 10.22 ± 4.42%, and a mean effective orifice area (EOA) of 1.85 ± 0.14 cm 2 , with valves of series 2 showing a lower REG ( P < .001). Following long-term durability testing, all valves of series 2 (n = 6) remained intact, demonstrating an MTP 9.11 ± 1.13 mm Hg, REG of 9.41 ± 4.25%, and EOA of 1.7 ± 0.1 cm 2 . Conclusions The potential of BC for use in CCS was demonstrated by developing a new biogenic polymer-based valve with excellent hemodynamic performance. These results warrant further investigation and development of this biomaterial.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Biogenic polymer-based heart valve for congenital cardiac surgery
Date Crossref
01/02/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Electrospun Nanofibers in Biomedical ApplicationsCardiac and Coronary Surgery TechniquesTissue Engineering and Regenerative Medicine

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.