Aller au contenu principal
Accès ouvert déclaré 2025 preprint

High frame rate RIXS spectroscopy using a JUNGFRAU detector with an iLGAD sensor

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Resonant inelastic X-ray scattering (RIXS) is a powerful photon-in, photon-out spectroscopy technique for probing electronic, magnetic, and lattice excitations in matter. Time-resolved RIXS extends this capability through a stroboscopic optical pump-probe scheme to characterize the time evolution of the photoexcitation and subsequent relaxation dynamics of a sample. This technique is, however, extremely photon-hungry, requiring high-repetition-rate and intense X-ray facilities. The Heisenberg RIXS (hRIXS) spectrometer at the Spectroscopy and Coherent Scattering (SCS) instrument of the European X-ray Free-Electron Laser (EuXFEL) is designed to exploit high-repetition-rates, while maintaining optimal time and energy resolution. In this work, we demonstrate the successful deployment of a JUNGFRAU detector equipped with an inverse Low Gain Avalanche Diode (iLGAD) sensor for time-resolved RIXS studies in the soft X-ray range, using the hRIXS spectrometer. A spatial resolution of $19.71 \pm 0.7~μ\mathrm{m}$ and a resolving power exceeding 10,000 were achieved at an unprecedented frame rate of 47 kHz. Intra-train resolved data measured with a high FEL peak fluence of $1.8~\mathrm{mJ/cm^{2}}$ for a 928.5 eV ph photon energy and 1.1 MHz repetition rate from cupric oxide (CuO) revealed a decrease in the emitted signal by ~10% over a time interval of $340~μ\mathrm{s}$, indicating FEL-induced effects that require monitoring when conducting high-repetition-rate experiments. These results establish the JUNGFRAU-iLGAD as a promising detector to harvest the full potential of the hRIXS spectrometer, and validate its suitability for soft X-ray applications.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Advanced X-ray Imaging TechniquesX-ray Spectroscopy and Fluorescence AnalysisElectron and X-Ray Spectroscopy Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.