Aller au contenu principal
Accès ouvert déclaré 2025 article

Regional impact of time-to-equilibrium on indirect Patlak whole-body parametric imaging: a multi-tissue class analysis at the entire body level

1Citations signalées — pas une note de qualité
9Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Patlak parametric imaging is widely employed for kinetic modeling due to its simplicity and robustness. The time-to-equilibrium (t*), which must be defined to estimate kinetic parameters, is currently set empirically and uniformly across the entire body. In this study, we evaluate the regional impact of varying t* values on kinetic parameter estimates using a multi-tissue segmentation approach at the whole-body level. Data from 53 patients who underwent one-hour dynamic 18 F-FDG PET/CT scans were retrospectively analyzed. Parametric maps of the net influx rate (K i ) and blood distribution volume (dv) were calculated for four t* values (10, 20, 30, and 45 min) using in-house software (PET KinetiX). Voxel-wise K i and dv values were extracted from 10 predefined tissue structures through automated segmentation. Using t* = 30 min as the widely accepted reference, relative mean errors and relative absolute mean errors of K i and dv estimated at t*shifts = 10, 20 and 45 min were calculated for each tissue. Pearson correlation coefficients between K i or dv reference values and those estimated at t* shifts = 10, 20, and 45 min were also computed. Compared to the reference t*30, K i estimates ranged from − 21.4% (liver) to 7.3% (SAT) at t*10, and from − 13.8% (lungs) to 2.4% (brain) at t*20. Median absolute bias was 12.8% at t*10 (6.5% brain to > 25% liver) and 8.6% at t*20 (3.2% brain to > 15% lungs and liver). At t*45, K i was consistently overestimated, with a median bias of 19.4% (2.7% brain to > 33% lungs and liver) and median absolute bias of 19.8% (5.5% brain to > 33% lungs and liver). For dv, biases ranged from − 25.2% (brain) to 8.6% (spleen) at t*10; − 13.7% (brain) to 5.7% (lungs) at t*20; − 15.5% (liver) to 8.8% (brain) at t*45. Median absolute biases were 14.0% at t*10 (9.8% heart to 25.2% brain), 9.4% at t*20 (7.7% heart to 14.1% brain), and 15% at t*45 (12.4% skeletal muscle to 18.5% brain). Regardless of t*, K i values exhibited strong linear correlations ( r > 0.7) across all organs, whereas dv correlations showed greater variability, falling below 0.7 in 80% of organs at t*45. Kinetic parameter sensitivity to time-to-equilibrium (t*) varies across organs in Patlak whole-body parametric imaging, underscoring the necessity of adopting flexible or adaptive t* values at the whole-body level.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Regional impact of time-to-equilibrium on indirect Patlak whole-body parametric imaging: a multi-tissue class analysis at the entire body level
Date Crossref
20/11/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Optical Imaging and Spectroscopy TechniquesMRI in cancer diagnosisMedical Imaging Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.