CT predicts intraprocedural hemodynamics with computational fluid dynamics in TMVR-ineligible patients undergoing M-TEER
Résumé fourni par la source
Background Hemodynamic outcomes in patients undergoing transcatheter mitral edge-to-edge repair (M-TEER) are difficult to predict. Computational fluid dynamics (CFD) is frequently used in biomedical engineering to simulate blood flow patterns under various conditions. Objectives We developed a standardized workflow for individualized CFD analyses to predict postinterventional mitral valve gradients and residual regurgitation following TEER. Methods Twenty patients with severe mitral regurgitation (MR) from two high-volume centers underwent full-cycle cardiac computed tomography before intervention. Based on the specific valve morphology, individualized CFD simulations were performed to calculate MR volumes prior to intervention and estimate hemodynamics after M-TEER. Results CFD analyses (mean age 80 ± 4 years, 55% male) showed excellent correlation between baseline proximal isovelocity surface area (PISA)-based MR volumes, median 40 ml [interquartile range (IQR): 30–49 ml], and CFD-based calculation, median 30 ml (IQR: 27–54 ml; R = 0.917; P < 0.001), as well as between baseline effective regurgitant orifice area (EROA) assessed in transesophageal echocardiography (TEE) and CFD-measured EROA ( R = 0.869; P < 0.001). After device implantation, the correlation between intraprocedural TEE-measured and CFD-estimated residual MR ( R = 0.949; P < 0.001) and EROA ( R = 0.841; P < 0.001) remained robust. Median postinterventional diastolic pressure gradient (TEE) was 2.8 mmHg (IQR: 1.7–4.0), which closely correlated with the CFD-estimated gradient of 1.4 mmHg (IQR: 2.3–4.5, R = 0.905; P < 0.001). Conclusions This is the first study to use a standardized CFD workflow for MR evaluation in patients undergoing TEER. In the future, CFD-based analyses may serve as a key diagnostic tool for procedural planning of TEER.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- CT predicts intraprocedural hemodynamics with computational fluid dynamics in TMVR-ineligible patients undergoing M-TEER
- Date Crossref
- 19/11/2025
- Éditeur
- Frontiers Media SA
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.