Improving cone-beam computed tomography image quality for transarterial therapy of liver malignancies: Evaluation of a motion correction algorithm with and without automated bone removal

1Citations signalées — pas une note de qualité
9Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Objectives: The objectives of the study are to compare the effect on image quality of a motion artifact correction algorithm (CAVAREC) alone versus in combination with an automated bone removal algorithm (ZIBOS) for motion-degraded intraprocedural liver cone-beam computed tomography (CBCT) images. Material and Methods: In this retrospective, two-center, Institutional Review Board (IRB)-approved study, 48 CBCTs from 41 patients were included. Inclusion criteria were (a) age ≥18; (b) liver CBCT with contrast injected at the main, right, or left hepatic artery; and (c) CBCT motion-degraded. Exclusion criteria were (a) no visible tumor and (b) CBCT not capturing the entire liver. The mean (standard deviation [SD]) age was 64 (7) years, 81% male. 65% had hepatocellular carcinoma and 35% metastatic cancer. 69% CBCTs were from transarterial radioembolization (TARE) mapping, 25% transarterial chemoembolization, and 6% TARE treatment. Mean (SD) maximum tumor diameter was 4.6 (2.7) cm. CBCT images were processed with CAVAREC (prototype, Siemens Healthineers AG, Forchheim, Germany) and CAVAREC + ZIBOS (work in progress, Comprehenso, Hannover, Germany). Using CoroEval, sharpness for two segmental arteries per case was obtained quantitatively. Three blinded interventional radiologists independently evaluated overall image quality on a 0–100 scale and large vessels, small vessels, vessel sharpness, tumor feeders, tumor blush, and streak artifacts on a −50 to +50 scale relative to uncorrected images. Results were analyzed with paired t- tests and Wilcoxon signed-rank tests, adjusting P -values with the Benjamini–Hochberg procedure. Results: On quantitative assessment, mean (SD) sharpness for uncorrected, CAVAREC, and CAVAREC + ZIBOS (C+Z) images was 0.281 (0.04), 0.287 (0.04), and 0.284 (0.04), respectively, P = 0.02 for uncorrected versus CAVAREC and P > 0.05 for other comparisons. On qualitative assessment, mean (SD) overall quality for uncorrected, CAVAREC, and C+Z images was 45 (14), 53 (16), and 53 (17), respectively, P < 0.001 for both uncorrected versus CAVAREC and uncorrected versus C+Z and P = 0.06 for CAVAREC versus C+Z. The mean preference for both CAVAREC and C+Z compared to uncorrected images for all parameters ranged from +4.3 to +9.5, P < 0.001, except tumor blush which was +1.6 for CAVAREC and +0.9 for C+Z, P > 0.05. CAVAREC versus C+Z was not significant for any parameter. Conclusion: Motion artifact correction of liver CBCT images using CAVAREC improves image quality significantly. According to observer studies, integrating the automated bone segmentation algorithm ZIBOS with CAVAREC does not degrade image quality.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Improving cone-beam computed tomography image quality for transarterial therapy of liver malignancies: Evaluation of a motion correction algorithm with and without automated bone removal
Date Crossref
20/11/2025
Éditeur
Scientific Scholar
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Medical Imaging Techniques and ApplicationsAdvanced X-ray and CT ImagingAdvanced Radiotherapy Techniques

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.