Evaluating Intraoperative Impedance Planimetry Findings Using a 16 cm Catheter in Patients Undergoing Peroral Endoscopic Myotomy ( POEM )
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
INTRODUCTION: Functional lumen imaging probe (FLIP) planimetry performed during peroral endoscopic myotomy (POEM) evaluates esophagogastric junction (EGJ) metrics. The 16 cm FLIP catheter allows for topographical assessment of the esophageal body, and previous intraoperative studies have only utilized the 8 cm catheter or combined data from both catheters. Our aim was to characterize the utility of the 16 cm catheter during POEM with respect to intraoperative tailoring of the myotomy length and intermediate outcomes after POEM. METHODS: We conducted a retrospective review of procedural and follow-up information of consecutive patients who underwent POEM with an intraoperative 16 cm catheter between January 2020 and September 2023. RESULTS: In 100 patients with intraoperative FLIP, the mean myotomy length was 8.2 cm. A tailored short myotomy (≤ 4 cm) using FLIP was performed in 10% of cases with comparable outcomes in LES obstruction and GERD metrics compared to > 4 cm myotomy length. On the basis of topographical FLIP findings, the myotomy was extended to capture spastic body features in 32% of cases including Type 2 achalasia (5), epiphrenic diverticulum (3) and prior myotomy (10). In intervention-naive patients, 70.5% achieved clinical success (Eckardt ≤ 3) at median follow-up of 30.9 months (IQR 6.5-40.9 months) with improvement in LES obstruction and GERD metrics among the intermediate follow-up cohort. An intraoperative post-myotomy EGJ diameter of ≥ 16 mm was associated with a lower rate of repeat intervention (2 vs. 5 patients, p = 0.038) and not associated with increased reflux outcomes. CONCLUSION: Intraoperative FLIP using the 16 cm catheter during POEM enables a tailored myotomy guided by both EGJ metrics and topographical assessment.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- Evaluating Intraoperative Impedance Planimetry Findings Using a 16 cm Catheter in Patients Undergoing Peroral Endoscopic Myotomy ( <scp>POEM</scp> )
- Date Crossref
- 18/11/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.